Data from http://www.kj-1.de/, accessed 7 July 2007.
Both of these two 8-coupled tanks originally operated on the Rosenberger Kleinbahn after their delivery from O & K. as their works #5216. In 1926, it was picked up by the Kleinbahnen des Kreises Jerichow I (KJI)
Like all other eastern Germany kleinbahn locomotives that survived World War II and taken into the DRG, they were renumbered in the 99 series. 4641 was scrapped in 1968 while the 4644 was taken into the Kleinbahnmuseum Lindenberg.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 15 / BR 99.464 |
Locobase ID | 8545 |
Railroad | Kleinbahn Landsberg - Rosenberg |
Country | Germany |
Whyte | 0-8-0T |
Number in Class | 2 |
Road Numbers | 15-16 / BR 99 4641, 4644 |
Gauge | 75 cm |
Number Built | 2 |
Builder | Orenstein & Koppel |
Year | 1912 |
Valve Gear | Heusinger |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.83 / 3.30 |
Engine Wheelbase (ft / m) | 10.83 / 3.30 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 10.83 / 3.30 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 52,249 / 23,700 |
Engine Weight (lbs / kg) | 52,249 / 23,700 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 52,249 / 23,700 |
Tender Water Capacity (gals / ML) | 1056 / 4 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.20 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 22 / 11 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 31.50 / 800 |
Boiler Pressure (psi / kPa) | 174 / 1200 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13.39" x 13.78" / 340x350 |
Tractive Effort (lbs / kg) | 11,600 / 5261.68 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.50 |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 57.03 / 5.30 |
Grate Area (sq ft / m2) | 12.27 / 1.14 |
Evaporative Heating Surface (sq ft / m2) | 577 / 53.63 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 577 / 53.63 |
Evaporative Heating Surface/Cylinder Volume | 256.91 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2135 |
Same as above plus superheater percentage | 2135 |
Same as above but substitute firebox area for grate area | 9923 |
Power L1 | 3507 |
Power MT | 591.90 |