Unspecified 2-2-2 Locomotives in Germany


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 11294)

Data from August Perdonnet, Traite Elementaire des Chemins de Fer, Tome Second (Paris: Garnier Freres, , 1860), pp. 570-572.

These singles set the trailing auxiliary axles behind the firebox and the driver and leading axles ahead. Axle compensations took two forms. The trailing axle was balanced tranversely while the driving and leading axles responded to longitudinal balancing. Perdonnet noted that this achieved the "milking stool", three-point stability desired by locomotive designers.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID11294
Railroad
CountryPrussia
Whyte2-2-2
Number in Class
Road Numbers
GaugeStd
Number Built
BuilderBorsig
Year1855
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)
Engine Wheelbase (ft / m)
Ratio of driving wheelbase to overall engine wheelbase
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)
Engine Weight (lbs / kg)62,082 / 28,160
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)72 / 1828
Boiler Pressure (psi / kPa)97.20 / 680
High Pressure Cylinders (dia x stroke) (in / mm)14.96" x 20.08" / 380x510
Tractive Effort (lbs / kg)5157 / 2339.18
Factor of Adhesion (Weight on Drivers/Tractive Effort)
Heating Ability
Tubes (number - dia) (in / mm)160 - 1.929" / 49
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)11.84 / 3.61
Firebox Area (sq ft / m2)64.88 / 6.03
Grate Area (sq ft / m2)11.62 / 1.08
Evaporative Heating Surface (sq ft / m2)893 / 83.02
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)893 / 83.02
Evaporative Heating Surface/Cylinder Volume218.60
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1129
Same as above plus superheater percentage1129
Same as above but substitute firebox area for grate area6306
Power L13476
Power MT

All material Copyright © SteamLocomotive.com