Halberstadt Blankenburger Eisenbahn 2-6-2 Locomotives in Germany


Class Details by Steve Llanso of Sweat House Media

Class BR 75 67 (Locobase 15325)

Data from Alfred Gieseler's Dampfmaschinen und Lokomotiven at [link], last accessed 26 July 2013.

The HBE's only real strains during World War Two came from meeting the ever-increasing traffic demands--the system suffered only minor damage from Allied action. These two Prairie tanks were delivered during the middle of the war as powerful freight switchers and haulers.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassBR 75 67
Locobase ID15325
RailroadHalberstadt Blankenburger Eisenbahn
CountryGermany
Whyte2-6-2T
Number in Class2
Road Numbers75 6776-75 6777
GaugeStd
Number Built2
BuilderBorsig
Year1943
Valve GearHeusinger
Locomotive Length and Weight
Driver Wheelbase (ft / m)11.81 / 3.60
Engine Wheelbase (ft / m)29.53 / 9
Ratio of driving wheelbase to overall engine wheelbase 0.40
Overall Wheelbase (engine & tender) (ft / m)29.53 / 9
Axle Loading (Maximum Weight per Axle) (lbs / kg)37,038 / 16,800
Weight on Drivers (lbs / kg)109,349 / 49,600
Engine Weight (lbs / kg)162,040 / 73,500
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)1848 / 7
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 2.80 / 3
Minimum weight of rail (calculated) (lb/yd / kg/m)61 / 30.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)49.20 / 1250
Boiler Pressure (psi / kPa)232.10 / 1600
High Pressure Cylinders (dia x stroke) (in / mm)21.26" x 23.62" / 540x600
Tractive Effort (lbs / kg)42,809 / 19417.86
Factor of Adhesion (Weight on Drivers/Tractive Effort) 2.55
Heating Ability
Tubes (number - dia) (in / mm)136 - 1.772" / 45
Flues (number - dia) (in / mm)26 - 5.236" / 133
Flue/Tube length (ft / m)12.14 / 3.70
Firebox Area (sq ft / m2)90.42 / 8.40
Grate Area (sq ft / m2)23.14 / 2.15
Evaporative Heating Surface (sq ft / m2)1166 / 108.28
Superheating Surface (sq ft / m2)448 / 41.60
Combined Heating Surface (sq ft / m2)1614 / 149.88
Evaporative Heating Surface/Cylinder Volume120.15
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation5371
Same as above plus superheater percentage6875
Same as above but substitute firebox area for grate area26,863
Power L111,081
Power MT670.22

All material Copyright © SteamLocomotive.com
Wes Barris