Data from [] (June 2002), supplemented by [
], last accessed 13 May 2011.
Sturdy mixed-traffic locomotives with Krauss-Helmholz trucks that were the last new steam locomotive design to appear in West Germany.
[] (a German steam locomotive parts supplier) gives the normal steaming capacity as 9,000 kg/hr. They were rated as capable of hauling a 440-short ton passenger train up a 2% grade at 80 kph.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | BR 65 |
Locobase ID | 2461 |
Railroad | Deutsche Bundesbahn |
Country | Germany |
Whyte | 2-8-4T |
Number in Class | 18 |
Road Numbers | BR 65 001-BR 65 018 |
Gauge | Std |
Number Built | 18 |
Builder | Krauss Maffei |
Year | 1951 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 17.22 / 5.25 |
Engine Wheelbase (ft / m) | 39.29 / 11.97 |
Ratio of driving wheelbase to overall engine wheelbase | 0.44 |
Overall Wheelbase (engine & tender) (ft / m) | 39.29 / 11.97 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 37,258 / 16,900 |
Weight on Drivers (lbs / kg) | 149,032 / 67,600 |
Engine Weight (lbs / kg) | 237,217 / 107,600 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 3696 / 14 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5.30 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 62 / 31 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 59.10 / 1500 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 22.44" x 25.98" / 570x660 |
Tractive Effort (lbs / kg) | 38,214 / 17333.60 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.90 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 124 - 1.732" / 44 |
Flues (number - dia) (in / mm) | 46 - 4.646" / 118 |
Flue/Tube length (ft / m) | 13.12 / 4 |
Firebox Area (sq ft / m2) | 159.25 / 14.80 |
Grate Area (sq ft / m2) | 28.73 / 2.67 |
Evaporative Heating Surface (sq ft / m2) | 1495 / 138.93 |
Superheating Surface (sq ft / m2) | 677 / 62.90 |
Combined Heating Surface (sq ft / m2) | 2172 / 201.83 |
Evaporative Heating Surface/Cylinder Volume | 125.71 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5835 |
Same as above plus superheater percentage | 7644 |
Same as above but substitute firebox area for grate area | 42,370 |
Power L1 | 14,104 |
Power MT | 834.56 |