Data from "Mikado Type Locomotive for Gold Coast Railway", Locomotive Magazine, Volume XXIX [29] (15 March 1923], pp. 65-66. Works numbers were 1377-1382 in 1922.
LM's report took special note of the relatively light axle loading for a freight engine generating 30,000 lb of tractive effort. The accompanying photo shows a relatively well-disguised Belpaire firebox set well back on a long boiler. A relatively capacious firebox included a brick arch, but the superheat ratio seems rather low at 11%.
Both Bissel trucks enjoyed a 3 1/2" (89 mm) play to either side and were equalized with the nearest driven axle. Inside-admission piston valve diameters measured 10" (254 mm) each.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 11 |
Locobase ID | 20952 |
Railroad | Takoradi Harbour |
Country | Ghana |
Whyte | 2-8-2 |
Number in Class | 6 |
Road Numbers | 11-16 |
Gauge | 3'6" |
Number Built | 6 |
Builder | Nasmyth Wilson |
Year | 1922 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 12.75 / 3.89 |
Engine Wheelbase (ft / m) | 28.75 / 8.76 |
Ratio of driving wheelbase to overall engine wheelbase | 0.44 |
Overall Wheelbase (engine & tender) (ft / m) | 51.69 / 15.76 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 28,448 / 12,904 |
Weight on Drivers (lbs / kg) | 113,187 / 51,341 |
Engine Weight (lbs / kg) | 158,816 / 72,038 |
Tender Loaded Weight (lbs / kg) | 73,987 / 33,560 |
Total Engine and Tender Weight (lbs / kg) | 232,803 / 105,598 |
Tender Water Capacity (gals / ML) | 3000 / 11.36 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 4.50 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 47 / 23.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 45 / 1143 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 20.5" x 24" / 521x610 |
Tractive Effort (lbs / kg) | 30,482 / 13826.42 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.71 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 159 - 2" / 51 |
Flues (number - dia) (in / mm) | 21 - 5.25" / 133 |
Flue/Tube length (ft / m) | 15.42 / 4.70 |
Firebox Area (sq ft / m2) | 150 / 13.94 |
Grate Area (sq ft / m2) | 32.14 / 2.99 |
Evaporative Heating Surface (sq ft / m2) | 1873 / 174.01 |
Superheating Surface (sq ft / m2) | 237 / 22.02 |
Combined Heating Surface (sq ft / m2) | 2110 / 196.03 |
Evaporative Heating Surface/Cylinder Volume | 204.29 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5142 |
Same as above plus superheater percentage | 5708 |
Same as above but substitute firebox area for grate area | 26,640 |
Power L1 | 6225 |
Power MT | 484.99 |