Data from Samuel Rendell (M. I Mech.E), "The Steam Locomotive: Fifty Years Ago and Now", read Saturday, 13 January 1906 and published in the Transactions of the Manchester Association of Engineers 1906 (January to March).
Little is said about this particular class, but note that it's an early product of a Manchester builder that would be world-famous in later years.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 8405 |
Railroad | Manchester, Sheffield & Lincolnshire |
Country | Great Britain |
Whyte | 0-4-2 |
Number in Class | |
Road Numbers | |
Gauge | Std |
Number Built | |
Builder | Sharp Brothers |
Year | 1847 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | 53,760 / 24,385 |
Tender Loaded Weight (lbs / kg) | 35,840 / 16,257 |
Total Engine and Tender Weight (lbs / kg) | 89,600 / 40,642 |
Tender Water Capacity (gals / ML) | 1200 / 4.55 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 60 / 1524 |
Boiler Pressure (psi / kPa) | 100 / 690 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 22" / 406x559 |
Tractive Effort (lbs / kg) | 7979 / 3619.22 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10.64 / 3.24 |
Firebox Area (sq ft / m2) | 68 / 6.32 |
Grate Area (sq ft / m2) | 11.40 / 1.06 |
Evaporative Heating Surface (sq ft / m2) | 859 / 79.83 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 859 / 79.83 |
Evaporative Heating Surface/Cylinder Volume | 167.79 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1140 |
Same as above plus superheater percentage | 1140 |
Same as above but substitute firebox area for grate area | 6800 |
Power L1 | 2342 |
Power MT |