Powell Duffryn Company 0-6-0 Locomotives in Great_Britain


Class Details by Steve Llanso of Sweat House Media

Class 10 (Locobase 10292)

Data from "New Locomotive for the Powell Duffryn Steam Coal Company", The Locomotive Magazine, Vol VIII (14 March 1903), p. 184

At the time, PD were one of the largest suppliers of Welsh coal to ''the Metropolis" and this class of compact saddle-tankers supported a traffic demand that moved nearly three million tons per year.

Hudswell, Clarke's "workmanship and finish" was pronounced to be "of the best" and reflecting great credit on the Leeds builder, who made" a specialty of locomotives intended for such services as that mentioned above."

Principal Dimensions by Steve Llanso of Middle Run Media
Class10
Locobase ID10292
RailroadPowell Duffryn Company
CountryGreat Britain
Whyte0-6-0ST
Number in Class3
Road Numbers
GaugeStd
Number Built3
BuilderHudswell, Clarke
Year1902
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)
Engine Wheelbase (ft / m)
Ratio of driving wheelbase to overall engine wheelbase
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)
Engine Weight (lbs / kg)
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)1500 / 5.68
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)49.50 / 1257
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)18" x 24" / 457x610
Tractive Effort (lbs / kg)21,364 / 9690.56
Factor of Adhesion (Weight on Drivers/Tractive Effort)
Heating Ability
Tubes (number - dia) (in / mm)
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)103 / 9.57
Grate Area (sq ft / m2)17 / 1.58
Evaporative Heating Surface (sq ft / m2)1055 / 98.05
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1055 / 98.05
Evaporative Heating Surface/Cylinder Volume149.25
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2720
Same as above plus superheater percentage2720
Same as above but substitute firebox area for grate area16,480
Power L12932
Power MT

All material Copyright © SteamLocomotive.com
Wes Barris