Data from "Rhondda & Swansea Bay Ry," The Locomotive Magazine, Vol VIII (13 June 1903), p. 405. Works numbers were 3581-3583. i 1895.
A sketch of the R&SB is presented in 10335. Here Locobase notes that these passenger tanks offered decent size and power for their requirements. In fact, they shared all basic dimensions and weighed nearly as much as the 0-6-2T radial tanks described in 10335.
Unlike the 0-6-2T radial tanks, however, the passenger trio found no home in the grouped Great Western Railwy that operated ex-R&SB locomotives beginning in January 1922.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 17 |
Locobase ID | 10336 |
Railroad | Rhondda & Swansea Bay |
Country | Great Britain |
Whyte | 2-4-2T |
Number in Class | 3 |
Road Numbers | 17-19 |
Gauge | Std |
Number Built | 3 |
Builder | Kitson & Co |
Year | 1895 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | 115,920 / 52,580 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 1980 / 7.50 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2.20 / 2 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 63 / 1600 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 26" / 457x660 |
Tractive Effort (lbs / kg) | 18,185 / 8248.59 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | 220 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 100 / 9.29 |
Grate Area (sq ft / m2) | 19.28 / 1.79 |
Evaporative Heating Surface (sq ft / m2) | 1171 / 108.83 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1171 / 108.83 |
Evaporative Heating Surface/Cylinder Volume | 152.92 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3085 |
Same as above plus superheater percentage | 3085 |
Same as above but substitute firebox area for grate area | 16,000 |
Power L1 | 3666 |
Power MT |