North Staffordshire 4-4-2 Locomotives in Great_Britain


Class Details by Steve Llanso of Sweat House Media

Class K (Locobase 20028)

Data from "North Staffordshire Railway", The Locomotive Magazine, Vol XVII (15 December 1911), p. 257; "Old and New Tank Locomotives, North Staffordshire Railway", Volume XVIII [18], No. 236 (15 April 1912), p. 69; and "Four-Coupled Tank, North Staffordshire Railway", Engineer, Volume CXIII [113] (22 March 1912), pp. 302 (diagram), 306 (description).

A septet of Atlantic passenger tanks with big Belpaire fireboxes and an unusually high superheater area, but a very small boiler for the cylinder volume. Its cylinders placed between inside created a very clean profile.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassK
Locobase ID20028
RailroadNorth Staffordshire
CountryGreat Britain
Whyte4-4-2T
Number in Class7
Road Numbers8, 45-46, 55, 13-14, 38
GaugeStd
Number Built7
BuilderStoke Works
Year1911
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 9.50 / 2.90
Engine Wheelbase (ft / m)31.12 / 9.49
Ratio of driving wheelbase to overall engine wheelbase 0.31
Overall Wheelbase (engine & tender) (ft / m)31.12 / 9.49
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)
Engine Weight (lbs / kg)152,320 / 69,091
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)2400 / 9.09
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 4.40 / 4
Minimum weight of rail (calculated) (lb/yd / kg/m)
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)72 / 1829
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)20" x 26" / 508x660
Tractive Effort (lbs / kg)19,644 / 8910.38
Factor of Adhesion (Weight on Drivers/Tractive Effort)
Heating Ability
Tubes (number - dia) (in / mm)112 - 1.875" / 48
Flues (number - dia) (in / mm)18 - 5" / 127
Flue/Tube length (ft / m)11.23 / 3.42
Firebox Area (sq ft / m2)133 / 12.36
Grate Area (sq ft / m2)21 / 1.95
Evaporative Heating Surface (sq ft / m2)1020 / 94.76
Superheating Surface (sq ft / m2)261 / 24.25
Combined Heating Surface (sq ft / m2)1281 / 119.01
Evaporative Heating Surface/Cylinder Volume107.89
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation3360
Same as above plus superheater percentage4032
Same as above but substitute firebox area for grate area25,536
Power L18193
Power MT

All material Copyright © SteamLocomotive.com