Compagnie Francaise des Mines du Laurium 0-6-0 Locomotives in Greece


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 15534)

Data from SACM diagram Nr. 83 from Societe Alsacienne de Constructions Mecaniques from locomotive book supplied by Dany Machi up at [link] as

Diagrammes des machines SACM construites a GRAFENSTADEN (October 2007).

Tube diameter is the interior measurement. Small industrial tank operated by the French company formed in the 19th Century that continued the exploitation of lead mines that were extracting ore near Athens during the Golden Age more than 2,000 years earlier.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID15534
RailroadCompagnie Francaise des Mines du Laurium
CountryGreece
Whyte0-6-0T
Number in Class
Road Numbers
GaugeStd
Number Built
BuilderSACM
Year
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 7.22 / 2.20
Engine Wheelbase (ft / m) 7.22 / 2.20
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m) 7.22 / 2.20
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)50,861 / 23,070
Engine Weight (lbs / kg)50,861 / 23,070
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)713 / 2.70
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 0.90 / 1
Minimum weight of rail (calculated) (lb/yd / kg/m)28 / 14
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)35.40 / 900
Boiler Pressure (psi / kPa)127.60 / 880
High Pressure Cylinders (dia x stroke) (in / mm)13.78" x 18.11" / 350x460
Tractive Effort (lbs / kg)10,536 / 4779.05
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.83
Heating Ability
Tubes (number - dia) (in / mm)105 - 1.378" / 35
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10.01 / 3.05
Firebox Area (sq ft / m2)47.36 / 4.40
Grate Area (sq ft / m2) 6.78 / 0.63
Evaporative Heating Surface (sq ft / m2)491 / 45.65
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)491 / 45.65
Evaporative Heating Surface/Cylinder Volume157.07
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation865
Same as above plus superheater percentage865
Same as above but substitute firebox area for grate area6043
Power L11753
Power MT227.96

All material Copyright © SteamLocomotive.com
Wes Barris