Data from Albert H Bone, "Some Recent Designs of Locomotives for Service on Continental Railways", Cassier's Magazine, 1910, pp. 570, 604.
A knuckle-dragging Consolidation, this design was built to haul "big loads up long gradients." Although it was limited to an axle-load of 13.3 tons (29,792 lb), the engine could put more weight on the rail by filling a tank located in the engine's frame with water drawn from the tender. At that point, total adhesion rose to 58.5 tons (131,040 lb). Radial traverse on the pony truck and 1/2" play on the second and fourth driving axles improved the locomotive's ability to negotiate curves.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 8947 |
Railroad | Anatolian |
Country | Greece |
Whyte | 2-8-0 |
Number in Class | |
Road Numbers | |
Gauge | Std |
Number Built | |
Builder | Henschel & Sohn |
Year | 1908 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 14.76 / 4.50 |
Engine Wheelbase (ft / m) | 23.62 / 7.20 |
Ratio of driving wheelbase to overall engine wheelbase | 0.62 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 156,087 / 70,800 |
Engine Weight (lbs / kg) | 156,087 / 70,800 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 65 / 32.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 53.10 / 1350 |
Boiler Pressure (psi / kPa) | 169.70 / 1170 |
High Pressure Cylinders (dia x stroke) (in / mm) | 23.62" x 24.8" / 600x630 |
Tractive Effort (lbs / kg) | 37,585 / 17048.29 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.15 |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 16.40 / 5 |
Firebox Area (sq ft / m2) | 138 / 12.80 |
Grate Area (sq ft / m2) | 32.28 / 3 |
Evaporative Heating Surface (sq ft / m2) | 1738 / 161.50 |
Superheating Surface (sq ft / m2) | 430 / 40 |
Combined Heating Surface (sq ft / m2) | 2168 / 201.50 |
Evaporative Heating Surface/Cylinder Volume | 138.19 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5478 |
Same as above plus superheater percentage | 6573 |
Same as above but substitute firebox area for grate area | 28,102 |
Power L1 | 7520 |
Power MT | 424.86 |