Data from Dr. R. Sanzin, "Die Lokomotiven auf der Intertionalen Austellung in Mailand 1906, 47. 4/4 gekuppelte Schlepptenderlokomotive von 760 mm Spurweite ...", Zeitschrift des Oesterreichischen Ingenieur- und Architeckten-Vereines, Volume LIX, Nr. 14 (5 April 1907), p 251.
Four-axle locomotive using the Klien-Lindner system, for a description of which see Locobase 3616. A tender engine of this size was rare on the 76 cm gauge and was smaller than the better-known Type 70.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 15555 |
| Railroad | Hungarian State |
| Country | Hungary |
| Whyte | 0-8-0 |
| Number in Class | |
| Road Numbers | |
| Gauge | 76 cm |
| Number Built | |
| Builder | M-V |
| Year | 1906 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 8.02 / 2.44 |
| Engine Wheelbase (ft / m) | 8.02 / 2.44 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 8.02 / 2.44 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 27,778 / 12,600 |
| Engine Weight (lbs / kg) | 27,778 / 12,600 |
| Tender Loaded Weight (lbs / kg) | 12,566 / 5700 |
| Total Engine and Tender Weight (lbs / kg) | 40,344 / 18,300 |
| Tender Water Capacity (gals / ML) | 528 / 2 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 12 / 6 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 25.60 / 650 |
| Boiler Pressure (psi / kPa) | 198.70 / 1370 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 9.84" x 11.81" / 250x300 |
| Tractive Effort (lbs / kg) | 7544 / 3421.90 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.68 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 71 - 1.732" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 7.55 / 2.30 |
| Firebox Area (sq ft / m2) | 26.91 / 2.50 |
| Grate Area (sq ft / m2) | 6.35 / 0.59 |
| Evaporative Heating Surface (sq ft / m2) | 259 / 24.07 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 259 / 24.07 |
| Evaporative Heating Surface/Cylinder Volume | 249.16 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1262 |
| Same as above plus superheater percentage | 1262 |
| Same as above but substitute firebox area for grate area | 5347 |
| Power L1 | 3210 |
| Power MT | 1019.06 |