Data from Vulcan Foundry catalogue, ca. 1920 ([]); and "Bogie Tank Engine for the East Indian Railways", Vulcan Foundry Locomotive Catalogue, No. 6, found on Flicker's Historical Locomotive Images website at [
] (Many thanks to Jorge Cerezo Toledo for his 26 June 2021 email containing links to several sites including the Vulcan Catalogue referred to above.). Works numbers were 1955-1984 in 1904 and 1199-1208 in 1908.
The photo shows a stubby engine with a relatively small boiler. A later batch of ten (works 3095-3119) was delivered in 1915. These appear to have been built to the same design.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1121 |
Locobase ID | 6383 |
Railroad | East Indian |
Country | India |
Whyte | 0-6-4T |
Number in Class | 30 |
Road Numbers | 1121-1150 |
Gauge | 5'6" |
Number Built | 30 |
Builder | Vulcan Foundry |
Year | 1904 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 16 / 4.88 |
Engine Wheelbase (ft / m) | 27.50 / 8.38 |
Ratio of driving wheelbase to overall engine wheelbase | 0.58 |
Overall Wheelbase (engine & tender) (ft / m) | 27.50 / 8.38 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 110,320 / 50,040 |
Engine Weight (lbs / kg) | 152,320 / 69,091 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 2400 / 9.09 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 3.40 / 3.10 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 61 / 30.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 54 / 1372 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 26" / 457x660 |
Tractive Effort (lbs / kg) | 21,216 / 9623.43 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.20 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 236 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10.47 / 3.19 |
Firebox Area (sq ft / m2) | 125 / 11.61 |
Grate Area (sq ft / m2) | 21.25 / 1.97 |
Evaporative Heating Surface (sq ft / m2) | 1257 / 116.78 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1257 / 116.78 |
Evaporative Heating Surface/Cylinder Volume | 164.15 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3400 |
Same as above plus superheater percentage | 3400 |
Same as above but substitute firebox area for grate area | 20,000 |
Power L1 | 3539 |
Power MT | 212.17 |