Class WU (Locobase 2481)

Some data from "Indian locomotive class WU" in Wikiwand at [link], last accessed 14 May 2023. Works numbers were 4783-4786 in 1943.

These small tank engine used for local passenger traffic. Although the EIR ordered the quartet in 1940, the EIR didn't receive them until 1943. At the time, the railway planned to add to the class. As the railway looked ahead to predicted increases in traffic demand, however, they concluded that these engines were too small and chose not to order any more.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassWU
Locobase ID2481
RailroadEast Indian Railways
CountryIndia
Whyte2-4-2T
Number in Class
Road Numbers2200-2203/26950-26953
Gauge5'6"
Number Built
BuilderVulcan Foundry
Year1943
Valve GearCaprotti
Locomotive Length and Weight
Driver Wheelbase (ft / m) 9.75 / 2.97
Engine Wheelbase (ft / m)27 / 8.23
Ratio of driving wheelbase to overall engine wheelbase 0.36
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg)36,960 / 16,765
Weight on Drivers (lbs / kg)73,920 / 33,530
Engine Weight (lbs / kg)141,695 / 64,272
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)1800 / 6.82
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 3.40 / 3
Minimum weight of rail (calculated) (lb/yd / kg/m)62 / 31
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)61.50 / 1562
Boiler Pressure (psi / kPa)210 / 1450
High Pressure Cylinders (dia x stroke) (in / mm)13" x 26" / 330x660
Tractive Effort (lbs / kg)12,753 / 5784.67
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.80
Heating Ability
Tubes (number - dia) (in / mm)
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)
Grate Area (sq ft / m2)18.50 / 1.72
Evaporative Heating Surface (sq ft / m2)742 / 68.96
Superheating Surface (sq ft / m2)182 / 16.91
Combined Heating Surface (sq ft / m2)924 / 85.87
Evaporative Heating Surface/Cylinder Volume185.77
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation3885
Same as above plus superheater percentage4662
Same as above but substitute firebox area for grate area
Power L1
Power MT