Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | BESA/HT |
Locobase ID | 4254 |
Railroad | |
Country | India |
Whyte | 2-8-2T |
Number in Class | |
Road Numbers | |
Gauge | 5'6" |
Number Built | |
Builder | Beyer, Peacock |
Year | 1924 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 14.50 / 4.42 |
Engine Wheelbase (ft / m) | 31 / 9.45 |
Ratio of driving wheelbase to overall engine wheelbase | 0.47 |
Overall Wheelbase (engine & tender) (ft / m) | 31 / 9.45 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 38,170 / 17,314 |
Weight on Drivers (lbs / kg) | 151,550 / 68,742 |
Engine Weight (lbs / kg) | 202,608 / 91,902 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 2000 / 7.58 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4 / 3.60 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 63 / 31.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 51 / 1295 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 22" x 26" / 559x660 |
Tractive Effort (lbs / kg) | 37,752 / 17124.04 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.01 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 272 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.37 / 3.47 |
Firebox Area (sq ft / m2) | 150 / 13.94 |
Grate Area (sq ft / m2) | 27 / 2.51 |
Evaporative Heating Surface (sq ft / m2) | 1568 / 145.67 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1568 / 145.67 |
Evaporative Heating Surface/Cylinder Volume | 137.07 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4860 |
Same as above plus superheater percentage | 4860 |
Same as above but substitute firebox area for grate area | 27,000 |
Power L1 | 3100 |
Power MT | 180.38 |