Data from DeGolyer, Vol 60, pp. 401. Works number was 53700 in September 1920.
Three years after the Handelsvereeniging had bought eight-coupled tanks from Baldwin (Locobase 14662), they returned for another similar, but somewhat enlarged engine. All of the drivers rolled in Rushton radial axles.
The engine was built as a wood burner, but it was delivered with an extra set of grates, netting, high exhaust, deflecting plate, straight stack to allow it to burn coal. There was no extra charge.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 14663 |
Railroad | Handelsvereeniging |
Country | Indonesia |
Whyte | 0-8-0T |
Number in Class | 1 |
Road Numbers | |
Gauge | 70 cm |
Number Built | 1 |
Builder | Baldwin |
Year | 1920 |
Valve Gear | Marshall |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8 / 2.44 |
Engine Wheelbase (ft / m) | 8 / 2.44 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 8 / 2.44 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 38,000 / 17,237 |
Engine Weight (lbs / kg) | 38,000 / 17,237 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 530 / 2.01 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 16 / 8 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 27 / 686 |
Boiler Pressure (psi / kPa) | 176 / 1210 |
High Pressure Cylinders (dia x stroke) (in / mm) | 10.5" x 14" / 267x356 |
Tractive Effort (lbs / kg) | 8552 / 3879.13 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.44 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 83 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10.50 / 3.20 |
Firebox Area (sq ft / m2) | 37 / 3.44 |
Grate Area (sq ft / m2) | 8.60 / 0.80 |
Evaporative Heating Surface (sq ft / m2) | 431 / 40.04 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 431 / 40.04 |
Evaporative Heating Surface/Cylinder Volume | 307.18 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1514 |
Same as above plus superheater percentage | 1514 |
Same as above but substitute firebox area for grate area | 6512 |
Power L1 | 3477 |
Power MT | 806.89 |