Data from [], a reprint of the Vulcan magazine last accessed 15 July 2007.
Although similar to and inspired by the Indian Railway Standard YD Mikados, this class of 10 (works #6156-6165) were oil-burners and had shorter tubes and flues. They were fitted with the usual Belpaire firebox, a single long dome casing for the sandbox and regulator, and roller bearings on the crosshead. The piston valves measured 8" in diameter.
NB: Tube length is an estimate based on the calculation of tube surface area by subtracting reported firebox heating surface from reported total evaporative heating surface
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Y |
Locobase ID | 8583 |
Railroad | Iraq State |
Country | Iraq |
Whyte | 2-8-2 |
Number in Class | 10 |
Road Numbers | |
Gauge | Metre |
Number Built | 10 |
Builder | Vulcan Foundry |
Year | 1953 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13.42 / 4.09 |
Engine Wheelbase (ft / m) | 27.75 / 8.46 |
Ratio of driving wheelbase to overall engine wheelbase | 0.48 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 86,968 / 39,448 |
Engine Weight (lbs / kg) | 126,926 / 57,573 |
Tender Loaded Weight (lbs / kg) | 90,328 / 40,972 |
Total Engine and Tender Weight (lbs / kg) | 217,254 / 98,545 |
Tender Water Capacity (gals / ML) | 3600 / 13.64 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1980 / 7494 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 36 / 18 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 48 / 1219 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 24" / 432x610 |
Tractive Effort (lbs / kg) | 22,109 / 10028.49 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.93 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 92 - 2.25" / 57 |
Flues (number - dia) (in / mm) | 21 - 5.25" / 133 |
Flue/Tube length (ft / m) | 15.17 / 4.62 |
Firebox Area (sq ft / m2) | 133 / 12.36 |
Grate Area (sq ft / m2) | 26 / 2.42 |
Evaporative Heating Surface (sq ft / m2) | 1381 / 128.35 |
Superheating Surface (sq ft / m2) | 285 / 26.49 |
Combined Heating Surface (sq ft / m2) | 1666 / 154.84 |
Evaporative Heating Surface/Cylinder Volume | 219.03 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4680 |
Same as above plus superheater percentage | 5476 |
Same as above but substitute firebox area for grate area | 28,010 |
Power L1 | 10,531 |
Power MT | 1067.83 |