Belfast Central 2-4-0 Locomotives in Ireland


Class Details by Steve Llanso of Sweat House Media

Class 3 (Locobase 15978)

Data from "Belfast Central Railway Locomotive [B 68674] = Photograph", archived at the State Library of South Australia, web location [link], last accessed 8 March 2015. Works number was 1707.

Originally bought by the BC for passenger work, this little tank was later adapted to auto-train service on the Great Northern. It pulled trailer cars outfitted to offer 21 first-class seats and 38 3rd class or nine 1st-class and 56 3rd-class passengers. Possessed of good power for the light duty, this auto-train was booked to run between Dublin and Howth (8 1/4 miles) and make 4 intermediate stops in 22 minutes.

Principal Dimensions by Steve Llanso of Middle Run Media
Class3
Locobase ID15978
RailroadBelfast Central
CountryIreland
Whyte2-4-0T
Number in Class1
Road Numbers
Gauge5'3"
Number Built1
BuilderBeyer, Peacock
Year1878
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 6.50 / 1.98
Engine Wheelbase (ft / m)17.62 / 5.37
Ratio of driving wheelbase to overall engine wheelbase 0.37
Overall Wheelbase (engine & tender) (ft / m)17.62 / 5.37
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)44,632 / 20,245
Engine Weight (lbs / kg)61,960 / 28,105
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)600 / 2.27
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)37 / 18.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)60 / 1524
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)14" x 20" / 356x508
Tractive Effort (lbs / kg)8885 / 4030.17
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.02
Heating Ability
Tubes (number - dia) (in / mm)115 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)52.70 / 4.90
Grate Area (sq ft / m2)10.50 / 0.98
Evaporative Heating Surface (sq ft / m2)602 / 55.93
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)602 / 55.93
Evaporative Heating Surface/Cylinder Volume168.94
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1680
Same as above plus superheater percentage1680
Same as above but substitute firebox area for grate area8432
Power L13886
Power MT383.90