Data from []. . (July 2002) and R M Livesey, "Rolling-Stock on the Principal Irish Narrow-Gauge Railways", Engineering, Volume 94, (2 August 1912), pp. 169-176, table on p. 175. Works number was 698 in 1904.
This engine had two lifetimes, one as a 2-6-0T for the C&VB and one as a 2-6-2T on the Clogher Valley Railway. As a 2-6-0T, the engine had similar power dimensions to the CVR's 0-4-2Ts and the opportunity to put more of the engine's weight on the drivers may have played a role in the conversion. After the modifications at the Aughnacloy Shops, however, the engine ran only five more years until the line closed. It was then scrapped.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 5083 |
Railroad | Castlederg & Victoria Bridge Tramway |
Country | Ireland |
Whyte | 2-6-0T |
Number in Class | 1 |
Road Numbers | 4 |
Gauge | 3' |
Number Built | 1 |
Builder | Hudswell, Clarke |
Year | 1904 |
Valve Gear | |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 7 / 2.13 |
Engine Wheelbase (ft / m) | 11 / 3.35 |
Ratio of driving wheelbase to overall engine wheelbase | 0.64 |
Overall Wheelbase (engine & tender) (ft / m) | 11 / 3.35 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 47,040 |
Engine Weight (lbs / kg) | 58,240 / 25,909 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 58,240 / 25,909 |
Tender Water Capacity (gals / ML) | 720 / 2.73 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.80 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 26 / 13 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 37 / 940 |
Boiler Pressure (psi / kPa) | 150 / 1030 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13.5" x 18" / 343x457 |
Tractive Effort (lbs / kg) | 11,304 / 5127.41 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.16 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 120 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 9.83 / 3 |
Firebox Area (sq ft / m2) | 54 / 5.02 |
Grate Area (sq ft / m2) | 9.25 / 0.86 |
Evaporative Heating Surface (sq ft / m2) | 596 / 55.39 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 596 / 55.39 |
Evaporative Heating Surface/Cylinder Volume | 199.86 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1388 |
Same as above plus superheater percentage | 1388 |
Same as above but substitute firebox area for grate area | 8100 |
Power L1 | 2686 |
Power MT | 377.65 |