Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 30, p. 217. Works number was 30453 in March 1907.
This Consolidation was originally intended for the National Railway of Nicaragua, but was sold to Frazar & Company as agents for the Japanese Bibai Company. Its specifications were essentially identical to locomotives delivered in 1893 (Locobase 10934) and later designated 9040.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Bibai |
Locobase ID | 13129 |
Railroad | Hokkaido Tanko Kisen/ JNR |
Country | Japan |
Whyte | 2-8-0 |
Number in Class | 1 |
Road Numbers | 1 |
Gauge | 3'6" |
Number Built | 1 |
Builder | Burnham, Williams & Co |
Year | 1907 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 12.25 / 3.73 |
Engine Wheelbase (ft / m) | 18.92 / 5.77 |
Ratio of driving wheelbase to overall engine wheelbase | 0.65 |
Overall Wheelbase (engine & tender) (ft / m) | 38.71 / 11.80 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 70,000 / 31,752 |
Engine Weight (lbs / kg) | 80,000 / 36,287 |
Tender Loaded Weight (lbs / kg) | 50,000 / 22,680 |
Total Engine and Tender Weight (lbs / kg) | 130,000 / 58,967 |
Tender Water Capacity (gals / ML) | 2500 / 9.47 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 29 / 14.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 43 / 1092 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 20" / 406x508 |
Tractive Effort (lbs / kg) | 16,193 / 7345.03 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.32 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 154 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.58 / 3.53 |
Firebox Area (sq ft / m2) | 88 / 8.18 |
Grate Area (sq ft / m2) | 17 / 1.58 |
Evaporative Heating Surface (sq ft / m2) | 1018 / 94.61 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1018 / 94.61 |
Evaporative Heating Surface/Cylinder Volume | 218.73 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2720 |
Same as above plus superheater percentage | 2720 |
Same as above but substitute firebox area for grate area | 14,080 |
Power L1 | 3592 |
Power MT | 452.51 |