Data from "Locomotives for Federated Malay States Railways," Railway Age Gazette, Volume 71, No 3 (16 July 1921), pp. 119-120. See also DeGolyer, Vol 63, pp. 160+. Works numbers were 54587-54596 in March 1921.
After the success of the twelvePacifics supplied by Baldwin in 1919, these Moguls and ten tank switchers (Locobase 14390) were procured in 1920-1921. The 2-6-0s were able to burn either coal or wood.
Again, an important selling point was said to be the speed of delivery. The 2-6-0s faced 2 1/2% grades and 16-deg curves.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | M 95 |
Locobase ID | 3235 |
Railroad | Federated Malay States Railways |
Country | Malaya |
Whyte | 2-6-0 |
Number in Class | 10 |
Road Numbers | 25-34 |
Gauge | Metre |
Number Built | 10 |
Builder | Baldwin |
Year | 1921 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 9.68 / 2.95 |
Engine Wheelbase (ft / m) | 15.91 / 4.85 |
Ratio of driving wheelbase to overall engine wheelbase | 0.61 |
Overall Wheelbase (engine & tender) (ft / m) | 39.24 / 11.96 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 23,149 / 10,500 |
Weight on Drivers (lbs / kg) | 52,000 / 23,587 |
Engine Weight (lbs / kg) | 62,001 / 28,123 |
Tender Loaded Weight (lbs / kg) | 47,000 / 21,319 |
Total Engine and Tender Weight (lbs / kg) | 109,001 / 49,442 |
Tender Water Capacity (gals / ML) | 2199 / 8.33 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 29 / 14.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 37 / 940 |
Boiler Pressure (psi / kPa) | 159.50 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 14.02" x 17.99" / 356x457 |
Tractive Effort (lbs / kg) | 12,957 / 5877.20 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.01 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 153 - 2.008" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 8.50 / 2.59 |
Firebox Area (sq ft / m2) | 88.05 / 8.18 |
Grate Area (sq ft / m2) | 13.13 / 1.22 |
Evaporative Heating Surface (sq ft / m2) | 762 / 70.79 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 762 / 70.79 |
Evaporative Heating Surface/Cylinder Volume | 237.06 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2094 |
Same as above plus superheater percentage | 2094 |
Same as above but substitute firebox area for grate area | 14,044 |
Power L1 | 3679 |
Power MT | 467.93 |