Lourenco Marques Articulated Locomotives in Mozambique


Class Details by Steve Llanso of Sweat House Media

Class 100 (Locobase 3610)

Wiener 1930 for data, See also "2-6-6-0" in Mallets built for export by North American locomotive builders at [], last accessed 13 October 2022; and , Railway World, (15 December 1911), p 1069.Works numbers were 50846-50847 in 1912

Based on the single Mallet delivered to the Natal Government Railways (Locobase 2776), this pair went to the CFM in 1912. Its motion used 10" (254 mm) piston valves to serve the HP cylinders and Richardson balance slide valves for the LP cylinders.

Locobase hasn't determined how long the pair remained in service, but notes that decades later the two were reported to still be in existence, " but derelict".

Principal Dimensions by Steve Llanso of Sweat House Media

Class100
Locobase ID3610
RailroadLourenco Marques
CountryMozambique
Whyte2-6-6-0
Number in Class2
Road Numbers100-101
Gauge3'6"
Number Built2
BuilderAlco-Schenectady
Year1912
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m) 8.33 / 2.54
Engine Wheelbase (ft / m)33.17 / 10.11
Ratio of driving wheelbase to overall engine wheelbase 0.25
Overall Wheelbase (engine & tender) (ft / m)60.24 / 18.36
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)177,600 / 80,558
Engine Weight (lbs / kg)195,001 / 88,451
Tender Loaded Weight (lbs / kg)99,199 / 44,996
Total Engine and Tender Weight (lbs / kg)294,200 / 133,447
Tender Water Capacity (gals / ML)4000 / 15.15
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 8.80 / 8
Minimum weight of rail (calculated) (lb/yd / kg/m)49 / 24.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)47.50 / 1207
Boiler Pressure (psi / kPa)200.20 / 13.80
High Pressure Cylinders (dia x stroke) (in / mm)17.52" x 25.98" / 445x660
Low Pressure Cylinders (dia x stroke) (in / mm)27.95" x 25.98" / 710x660
Tractive Effort (lbs / kg)41,020 / 18606.38
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.33
Heating Ability
Tubes (number - dia) (in / mm)230 - 2.244" / 57
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)18.01 / 5.49
Firebox Area (sq ft / m2)125.08 / 11.62
Grate Area (sq ft / m2)40.04 / 3.72
Evaporative Heating Surface (sq ft / m2)2548 / 236.71
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)2548 / 236.71
Evaporative Heating Surface/Cylinder Volume351.49
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation8016
Same as above plus superheater percentage8016
Same as above but substitute firebox area for grate area25,041
Power L12726
Power MT203.03

All material Copyright © SteamLocomotive.com