Data from the table presented on pages 370, 372 of the Groupe VI. - GTnie civil. - Moyens de transport. DeuxiFme partie. Classes 32 (Tome I), part of the series of Rapports du Jury Internationale of the Exposition Unverselle Internationale de 1900 Paris Exposition, hosted on the website of Le Conservatoire numTrique des Arts & MTtiers ([], Accessed 21 August 2005). See also "Passenger Engine and Tender: Central Netherlands Railway",
Most noticeable difference between this design and most other Eight-wheelers of the time is the set of large-diameter Serve fire tubes with eight internal ribs. Otherwise, this is a relatively small locomotive with a Belpaire firebox.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 27 |
Locobase ID | 6787 |
Railroad | Netherlands State |
Country | Netherlands |
Whyte | 4-4-0 |
Number in Class | 1 |
Road Numbers | |
Gauge | Std |
Number Built | 1 |
Builder | Neilson, Reid |
Year | 1900 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 9 / 2.74 |
Engine Wheelbase (ft / m) | 22.46 / 6.85 |
Ratio of driving wheelbase to overall engine wheelbase | 0.40 |
Overall Wheelbase (engine & tender) (ft / m) | 45.67 / 13.92 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 62,717 / 28,448 |
Engine Weight (lbs / kg) | 102,318 / 46,411 |
Tender Loaded Weight (lbs / kg) | 81,196 / 36,830 |
Total Engine and Tender Weight (lbs / kg) | 183,514 / 83,241 |
Tender Water Capacity (gals / ML) | 3720 / 14.09 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2.50 / 2 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 52 / 26 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 84.50 / 2146 |
Boiler Pressure (psi / kPa) | 150 / 1030 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 26" / 457x660 |
Tractive Effort (lbs / kg) | 12,711 / 5765.62 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.93 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 94 - 2.76" / 70 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.05 / 3.37 |
Firebox Area (sq ft / m2) | 107.80 / 10.01 |
Grate Area (sq ft / m2) | 23 / 2.14 |
Evaporative Heating Surface (sq ft / m2) | 1443 / 134.06 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1443 / 134.06 |
Evaporative Heating Surface/Cylinder Volume | 188.44 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3450 |
Same as above plus superheater percentage | 3450 |
Same as above but substitute firebox area for grate area | 16,170 |
Power L1 | 5468 |
Power MT | 384.42 |