Netherlands State 4-4-0 Locomotives in Netherlands


Class Details by Steve Llanso of Sweat House Media

Class 27 (Locobase 6787)

Data from the table presented on pages 370, 372 of the Groupe VI. - GTnie civil. - Moyens de transport. DeuxiFme partie. Classes 32 (Tome I), part of the series of Rapports du Jury Internationale of the Exposition Unverselle Internationale de 1900 Paris Exposition, hosted on the website of Le Conservatoire numTrique des Arts & MTtiers ([link], Accessed 21 August 2005). See also "Passenger Engine and Tender: Central Netherlands Railway",

Most noticeable difference between this design and most other Eight-wheelers of the time is the set of large-diameter Serve fire tubes with eight internal ribs. Otherwise, this is a relatively small locomotive with a Belpaire firebox.

Principal Dimensions by Steve Llanso of Middle Run Media
Class27
Locobase ID6787
RailroadNetherlands State
CountryNetherlands
Whyte4-4-0
Number in Class1
Road Numbers
GaugeStd
Number Built1
BuilderNeilson, Reid
Year1900
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)9 / 2.74
Engine Wheelbase (ft / m)22.46 / 6.85
Ratio of driving wheelbase to overall engine wheelbase 0.40
Overall Wheelbase (engine & tender) (ft / m)45.67 / 13.92
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)62,717 / 28,448
Engine Weight (lbs / kg)102,318 / 46,411
Tender Loaded Weight (lbs / kg)81,196 / 36,830
Total Engine and Tender Weight (lbs / kg)183,514 / 83,241
Tender Water Capacity (gals / ML)3720 / 14.09
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 2.50 / 2
Minimum weight of rail (calculated) (lb/yd / kg/m)52 / 26
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)84.50 / 2146
Boiler Pressure (psi / kPa)150 / 1030
High Pressure Cylinders (dia x stroke) (in / mm)18" x 26" / 457x660
Tractive Effort (lbs / kg)12,711 / 5765.62
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.93
Heating Ability
Tubes (number - dia) (in / mm)94 - 2.76" / 70
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)11.05 / 3.37
Firebox Area (sq ft / m2)107.80 / 10.01
Grate Area (sq ft / m2)23 / 2.14
Evaporative Heating Surface (sq ft / m2)1443 / 134.06
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1443 / 134.06
Evaporative Heating Surface/Cylinder Volume188.44
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation3450
Same as above plus superheater percentage3450
Same as above but substitute firebox area for grate area16,170
Power L15468
Power MT384.42

All material Copyright © SteamLocomotive.com
Wes Barris