Hejaz 2-8-0 Locomotives in Palestine


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 16111)

Data from "2-8-0 Goods Locomotive, Hedjaz[sic] Railway", The Locomotive, Volume XVII [17] (14 October 1911), p. 226. See also "The Hedjaz Railway", Locomotive Magazine, Volume XXI [21] (15 April 1915), pp. 79-81.

In a departure from usual practice, Arnold Jung supplied Consolidation locomotives that had the lead truck placed behind the cylinders. The top of the boiler showed a cylindrical dome over the front driven axle and a square sand box over the second driver.


Class unknown (Locobase 20937)

Data from "1D (4/5 gek.) Zweizylinder-Guterug-Lokomotive gebaut fur die Chemin de Fer Hamidie du Hedjaz, Syrien" data card.

Principal Dimensions by Steve Llanso of Sweat House Media

Classunknownunknown
Locobase ID16111 20937
RailroadHejazHejaz
CountryPalestinePalestine
Whyte2-8-02-8-0
Number in Class30
Road Numbers
Gauge105 cm105 cm
Number Built30
BuilderJungSaxon
Year1908
Valve GearStephensonWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)10.85 / 3.3010.85 / 3.60
Engine Wheelbase (ft / m)14.27 / 4.3514.27 / 5.55
Ratio of driving wheelbase to overall engine wheelbase 0.76 0.76
Overall Wheelbase (engine & tender) (ft / m)
Axle Loading (Maximum Weight per Axle) (lbs / kg) / 10,000
Weight on Drivers (lbs / kg) / 39,520
Engine Weight (lbs / kg)103,397 / 46,900103,397 / 44,000
Tender Loaded Weight (lbs / kg)89,618 / 40,65089,618
Total Engine and Tender Weight (lbs / kg)193,015 / 87,550193,015 / 44,000
Tender Water Capacity (gals / ML)4752 / 184752
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 5.50 / 5 5.50
Minimum weight of rail (calculated) (lb/yd / kg/m)
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)40.90 / 104040.90 / 1040
Boiler Pressure (psi / kPa)175.50 / 12.10175.50 / 11.80
High Pressure Cylinders (dia x stroke) (in / mm)16.14" x 19.69" / 410x50016.14" x 19.69" / 410x500
Tractive Effort (lbs / kg)18,708 / 8485.8218,708 / 8485.82
Factor of Adhesion (Weight on Drivers/Tractive Effort)
Heating Ability
Tubes (number - dia) (in / mm)
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2) / 7.55
Grate Area (sq ft / m2)17.76 / 1.6517.76 / 1.78
Evaporative Heating Surface (sq ft / m2)1435 / 133.301435 / 122.61
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1435 / 133.301435 / 122.61
Evaporative Heating Surface/Cylinder Volume307.77307.77
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation31173117
Same as above plus superheater percentage31173117
Same as above but substitute firebox area for grate area
Power L1
Power MT

All material Copyright © SteamLocomotive.com