Data from image 54b of FEPASA website ([], last accessed 27 December 2010). Works numbers were in the 19200 range.
Bought at the same time as the Moguls described in Locobase 11941-11942, these Belpaire-firebox Ten-wheelers were smaller and less powerful and had straight boilers.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | N |
Locobase ID | 11944 |
Railroad | FC Central Paraguay (FCCP) |
Country | Paraguay |
Whyte | 4-6-0 |
Number in Class | 10 |
Road Numbers | 221-230 |
Gauge | Std |
Number Built | 10 |
Builder | North British |
Year | 1910 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.15 / 3.10 |
Engine Wheelbase (ft / m) | 16.15 / 4.92 |
Ratio of driving wheelbase to overall engine wheelbase | 0.63 |
Overall Wheelbase (engine & tender) (ft / m) | 45.42 / 13.84 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 72,342 / 32,814 |
Engine Weight (lbs / kg) | 104,155 / 47,244 |
Tender Loaded Weight (lbs / kg) | 92,956 / 42,164 |
Total Engine and Tender Weight (lbs / kg) | 197,111 / 89,408 |
Tender Water Capacity (gals / ML) | 4195 / 15.89 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 8.40 / 8 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 40 / 20 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 56 / 1422 |
Boiler Pressure (psi / kPa) | 170 / 1170 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 24" / 432x610 |
Tractive Effort (lbs / kg) | 17,897 / 8117.95 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.04 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 190 - 2.008" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.33 |
Firebox Area (sq ft / m2) | 103.83 / 9.65 |
Grate Area (sq ft / m2) | 16.89 / 1.57 |
Evaporative Heating Surface (sq ft / m2) | 1236 / 114.85 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1236 / 114.85 |
Evaporative Heating Surface/Cylinder Volume | 196.03 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2871 |
Same as above plus superheater percentage | 2871 |
Same as above but substitute firebox area for grate area | 17,651 |
Power L1 | 4417 |
Power MT | 403.82 |