Lima a Chilca 2-8-0 Locomotives in Peru


Class Details by Steve Llanso of Sweat House Media

Class Pachacamac (Locobase 14004)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 44, p. 215. Works number was 39904 in May 1913.

Separated by 75 km (46.6 miles), Lima and Chilca (to its south) began constructing a railway between them in February 1913. At the same time, the narrow gauge ordered this modestly scaled Consolidation.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassPachacamac
Locobase ID14004
RailroadLima a Chilca
CountryPeru
Whyte2-8-0
Number in Class1
Road Numbers1
Gauge3'
Number Built1
BuilderBaldwin
Year1913
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)11.33 / 3.45
Engine Wheelbase (ft / m)17.83 / 5.43
Ratio of driving wheelbase to overall engine wheelbase 0.64
Overall Wheelbase (engine & tender) (ft / m)39 / 11.89
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)60,550 / 27,465
Engine Weight (lbs / kg)69,350 / 31,457
Tender Loaded Weight (lbs / kg)40,000 / 18,144
Total Engine and Tender Weight (lbs / kg)109,350 / 49,601
Tender Water Capacity (gals / ML)2000 / 7.58
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)4 / 4
Minimum weight of rail (calculated) (lb/yd / kg/m)25 / 12.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)36 / 914
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)14" x 18" / 356x457
Tractive Effort (lbs / kg)13,328 / 6045.49
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.54
Heating Ability
Tubes (number - dia) (in / mm)138 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10 / 3.05
Firebox Area (sq ft / m2)84 / 7.80
Grate Area (sq ft / m2)13.70 / 1.27
Evaporative Heating Surface (sq ft / m2)800 / 74.32
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)800 / 74.32
Evaporative Heating Surface/Cylinder Volume249.45
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2192
Same as above plus superheater percentage2192
Same as above but substitute firebox area for grate area13,440
Power L13652
Power MT531.88