Data from Dr Jonathan Smith, [] . Works numbers were 26483-26484 in 1951.
The first of the Mikado pair remained with the FCHH (nicknamed" tren Macho", but the 105 was reassigned to FC Cuzco-Santa Ana as their 122.
Data from Dr Jonathan Smith, []
Data from Dr Jonathan Smith, []
Principal Dimensions by Steve Llanso of Middle Run Media | |||
---|---|---|---|
Class | 11 | CdeP 10 | CdeP 70 |
Locobase ID | 4581 | 4577 | 4578 |
Railroad | Huancayo á Huancavelica (ENAFER) | ENAFER | ENAFER |
Country | Peru | Peru | Peru |
Whyte | 2-8-2 | 2-8-2 | 2-8-2 |
Number in Class | 2 | ||
Road Numbers | 11-12/104-105 | ||
Gauge | 3' | Std | Std |
Number Built | 2 | ||
Builder | Henschel & Sohn | ||
Year | 1951 | ||
Valve Gear | |||
Locomotive Length and Weight | |||
Driver Wheelbase (ft / m) | |||
Engine Wheelbase (ft / m) | |||
Ratio of driving wheelbase to overall engine wheelbase | |||
Overall Wheelbase (engine & tender) (ft / m) | |||
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |||
Weight on Drivers (lbs / kg) | 94,080 / 42,674 | 134,400 / 60,963 | 145,600 / 66,043 |
Engine Weight (lbs / kg) | 132,160 / 59,947 | 170,240 / 77,220 | 165,760 / 75,188 |
Tender Loaded Weight (lbs / kg) | |||
Total Engine and Tender Weight (lbs / kg) | |||
Tender Water Capacity (gals / ML) | |||
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |||
Minimum weight of rail (calculated) (lb/yd / kg/m) | 39 / 19.50 | 56 / 28 | 61 / 30.50 |
Geometry Relating to Tractive Effort | |||
Driver Diameter (in / mm) | 42 / 1067 | 52 / 1321 | 52 / 1321 |
Boiler Pressure (psi / kPa) | 175 / 1210 | 180 / 1240 | 200 / 1380 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 22" / 457x559 | 20" x 26" / 508x660 | 20" x 28" / 508x711 |
Tractive Effort (lbs / kg) | 25,245 / 11450.95 | 30,600 / 13879.94 | 36,615 / 16608.30 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.73 | 4.39 | 3.98 |
Heating Ability | |||
Tubes (number - dia) (in / mm) | |||
Flues (number - dia) (in / mm) | |||
Flue/Tube length (ft / m) | |||
Firebox Area (sq ft / m2) | |||
Grate Area (sq ft / m2) | 27 / 2.51 | 37 / 3.44 | 25 / 2.32 |
Evaporative Heating Surface (sq ft / m2) | 1400 / 130.11 | 2121 / 197.12 | 1717 / 159.57 |
Superheating Surface (sq ft / m2) | 405 / 37.64 | 341 / 31.69 | |
Combined Heating Surface (sq ft / m2) | 1805 / 167.75 | 2121 / 197.12 | 2058 / 191.26 |
Evaporative Heating Surface/Cylinder Volume | 216.06 | 224.35 | 168.65 |
Computations Relating to Power Output (More Information) | |||
Robert LeMassena's Power Computation | 4725 | 6660 | 5000 |
Same as above plus superheater percentage | 5765 | 6660 | 5850 |
Same as above but substitute firebox area for grate area | |||
Power L1 | |||
Power MT |