Data from DeGolyer, Vol 78, pp. 356. See also a listing of Sugar Centrals in the Philippines in the American Chamber of Commerce of the Philippines Journal (January 1922), p. 30. Works number was 58473 in June 1925.
The track gauge tells us all about this many-wheeled wood-burning plantation eight-coupled locomotive. It put relatively little weight on its axles, had nearly square cylinders, and sported a small spark-arresting Rushton Improved cabbage stack.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 3 |
Locobase ID | 15407 |
Railroad | Victorias Milling Company |
Country | Philippines |
Whyte | 0-8-0 |
Number in Class | 1 |
Road Numbers | 3 |
Gauge | 2' |
Number Built | 1 |
Builder | Baldwin |
Year | 1925 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 7.83 / 2.39 |
Engine Wheelbase (ft / m) | 7.83 / 2.39 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 31.02 / 9.45 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 8960 |
Weight on Drivers (lbs / kg) | 35,000 / 15,876 |
Engine Weight (lbs / kg) | 35,000 / 15,876 |
Tender Loaded Weight (lbs / kg) | 35,800 / 16,239 |
Total Engine and Tender Weight (lbs / kg) | 70,800 / 32,115 |
Tender Water Capacity (gals / ML) | 1700 / 6.44 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 15 / 7.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 24 / 610 |
Boiler Pressure (psi / kPa) | 165 / 1140 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11" x 12" / 279x305 |
Tractive Effort (lbs / kg) | 8485 / 3848.74 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.12 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 65 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10 / 3.05 |
Firebox Area (sq ft / m2) | 34 / 3.16 |
Grate Area (sq ft / m2) | 7 / 0.65 |
Evaporative Heating Surface (sq ft / m2) | 372 / 34.56 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 372 / 34.56 |
Evaporative Heating Surface/Cylinder Volume | 281.84 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1155 |
Same as above plus superheater percentage | 1155 |
Same as above but substitute firebox area for grate area | 5610 |
Power L1 | 2710 |
Power MT | 682.80 |