0-6-0 Steam Locomotives in Russia

Moskau-Brest


Class Details by Steve Llanso of Sweat House Media

Class Type 77 (Locobase 21216)

Data from "Locomotives", Type 77, Usines du Creusot-Schneider et Cie (Creusot: A Temporal, 1875), n.a. Works numbers were 1574-1576.

This small trio offered a compact profile with a tall, vase-like spark-arresting stack over a pair of cylinders fitted outside the frames. A short dome sat over the first driven axle. A taller dome sat on an octagonal plnth set over the second axle. Long, rectangular water tanks flanked the boiler and the cab. Its bunker had a sleigh-like wood basket.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassType 77
Locobase ID21216
RailroadMoskau-Brest
CountryRussia
Whyte0-6-0T
Number in Class3
Road NumbersD 1-D 3/HO 376-HO 378
Gauge5'
Number Built3
BuilderSchneider-Creusot
Year1873
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)10.83 / 3.30
Engine Wheelbase (ft / m)10.83 / 3.30
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m)10.83 / 3.30
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)65,036 / 29,500
Engine Weight (lbs / kg)65,036 / 29,500
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)36 / 18
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)41.70 / 1060
Boiler Pressure (psi / kPa)126.20 / 870
High Pressure Cylinders (dia x stroke) (in / mm)16.54" x 18.9" / 420x480
Tractive Effort (lbs / kg)13,301 / 6033.24
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.89
Heating Ability
Tubes (number - dia) (in / mm)181 - 1.732" / 44
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m) 9.19 / 2.80
Firebox Area (sq ft / m2)53.82 / 5
Grate Area (sq ft / m2) 8.40 / 0.78
Evaporative Heating Surface (sq ft / m2)840 / 78
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)840 / 78
Evaporative Heating Surface/Cylinder Volume178.72
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1060
Same as above plus superheater percentage1060
Same as above but substitute firebox area for grate area6792
Power L12070
Power MT210.51

All material Copyright © SteamLocomotive.com
Wes Barris