Data from "Russian Goods Locomotive," Engineering, Volume 18 (25 December 1874), pp. 490-491.
Engineering noted a few differences from the typical goods locomotive of the time. One was a slight backwards rake to the firebox's back wall, which slightly increased the grate area. Otherwise, the engine had a common profile that had the dome well forward, just behind the stack and just ahead of a small drum-shaped sandbox. The stack had a flared spark-arresting casing around the straight pipe. A much smaller onion dome sat over over the firebox and inside the cab. One criticism concerned the reversing lever, which was "...very short, and has a most unusually -- and we consider inconveniently -- large angular range."
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 13566 |
Railroad | St Petersburg-Warsaw |
Country | Russia |
Whyte | 0-6-0 |
Number in Class | |
Road Numbers | |
Gauge | 5' |
Number Built | |
Builder | StPW |
Year | 1874 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 11.15 / 3.40 |
Engine Wheelbase (ft / m) | 11.15 / 3.40 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 70,548 / 32,000 |
Engine Weight (lbs / kg) | 70,548 / 32,000 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 39 / 19.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 51.20 / 1300 |
Boiler Pressure (psi / kPa) | 124.70 / 860 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17.32" x 24.02" / 440x610 |
Tractive Effort (lbs / kg) | 14,917 / 6766.25 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.73 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 162 - 1.969" / 50 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 13.78 / 4.20 |
Firebox Area (sq ft / m2) | 90.42 / 8.40 |
Grate Area (sq ft / m2) | 16.15 / 1.50 |
Evaporative Heating Surface (sq ft / m2) | 1249 / 116 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1249 / 116 |
Evaporative Heating Surface/Cylinder Volume | 190.69 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2014 |
Same as above plus superheater percentage | 2014 |
Same as above but substitute firebox area for grate area | 11,275 |
Power L1 | 2764 |
Power MT | 259.12 |