Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 21, p. 159. Works numbers were 15836-15849 in April 1898.
These Vauclain compound Consolidations were identical to the large Vladicaucase order that shipped in 1896 (Locobase 12173) and the later Moscow-Vindbau deliveries (Locobase 3222) that had 14" (456 mm) HP cylinders.
This set soon operated on the Moscow-Kursk Railway.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 803 |
Locobase ID | 12265 |
Railroad | South Eastern |
Country | Russia |
Whyte | 2-8-0 |
Number in Class | 14 |
Road Numbers | 803-816 |
Gauge | 5' |
Number Built | 14 |
Builder | Burnham, Williams & Co |
Year | 1898 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13.42 / 4.09 |
Engine Wheelbase (ft / m) | 21.33 / 6.50 |
Ratio of driving wheelbase to overall engine wheelbase | 0.63 |
Overall Wheelbase (engine & tender) (ft / m) | 45.58 / 13.89 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 116,420 / 52,807 |
Engine Weight (lbs / kg) | 132,000 / 59,874 |
Tender Loaded Weight (lbs / kg) | 85,000 / 38,555 |
Total Engine and Tender Weight (lbs / kg) | 217,000 / 98,429 |
Tender Water Capacity (gals / ML) | 4200 / 15.91 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 49 / 24.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 50 / 1270 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13.5" x 26" / 343x660 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 23" x 26" / 584x660 |
Tractive Effort (lbs / kg) | 21,569 / 9783.55 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.40 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 259 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 13.50 / 4.11 |
Firebox Area (sq ft / m2) | 130.48 / 12.13 |
Grate Area (sq ft / m2) | 26.25 / 2.44 |
Evaporative Heating Surface (sq ft / m2) | 1944 / 180.67 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1944 / 180.67 |
Evaporative Heating Surface/Cylinder Volume | 451.31 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4725 |
Same as above plus superheater percentage | 4725 |
Same as above but substitute firebox area for grate area | 23,486 |
Power L1 | 3115 |
Power MT | 235.95 |