Data from "Locomotoras de Vapor--Locomotora HVL Nñ 3" on the Centro de Inciativas Ferroviarias--Vapor--Madrid website at [], last accessed 8 August 2020. Although ordered from Tubize and given works number 1896, but the actual production location was the Blanc Misseron of the Ateliers de Constructions du Nord de la France (ANF), its works number was 168.
The HLV railway connected the colliery at Matallana to the station at Vasco-Leonesa and its junction with the FC La Robla. This little tank wasn't too different from many others, but the CIF account singles out the split smokebox doors (as opposed to the usual side-hinged single door), manual oiliing of the valve gear, and cylinders placed well ahead of the smokebox.
In 1995, the CIFM acquired the 3 for preservation at La Poveda.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 3 |
Locobase ID | 20786 |
Railroad | Hullera Vasco-Leonesa |
Country | Spain |
Whyte | 0-6-0T |
Number in Class | 1 |
Road Numbers | 3 |
Gauge | Metre |
Number Built | 1 |
Builder | Tubize |
Year | 1896 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.50 / 3.20 |
Engine Wheelbase (ft / m) | 10.50 / 3.20 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 10.50 / 3.20 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 62,832 / 28,500 |
Engine Weight (lbs / kg) | 62,832 / 28,500 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 620 / 2.35 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 35 / 17.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 33.40 / 848 |
Boiler Pressure (psi / kPa) | 171.10 / 1180 |
High Pressure Cylinders (dia x stroke) (in / mm) | 12.99" x 11.81" / 330x300 |
Tractive Effort (lbs / kg) | 8677 / 3935.83 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 7.24 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 163 - 1.378" / 35 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 6.59 / 2.01 |
Firebox Area (sq ft / m2) | 49.73 / 4.62 |
Grate Area (sq ft / m2) | 9.04 / 0.84 |
Evaporative Heating Surface (sq ft / m2) | 431 / 40 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 431 / 40 |
Evaporative Heating Surface/Cylinder Volume | 237.92 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1547 |
Same as above plus superheater percentage | 1547 |
Same as above but substitute firebox area for grate area | 8509 |
Power L1 | 3573 |
Power MT | 376.10 |