Associacio Reconstruccio Material Ferrviari website at [] and the Locomotives of the SFG website at [], last accessed 16 November 2011. Works numbers were 2343 and 2392 in 1890.
The SFG site says that these were very similar to a group of tanks bought for the Sant Feliu de Gufxols a Gerona in 1890-1893. But "La Panderola" only operated the pair in Feliu for about 3-4 months because the design was so unsatisfactory. They were viewed as difficult to operate because they were cross-compounds, and they rode roughly. So both were transferred to Gerona, where it served for the rest of its career. For a time it was used on a tramway.
The 7 was later cosmetically restored for display.
Both sources report that the firebox had a 0.9 sq m area. Locobase believes that it is an incredibly low number and has used the figure as a grate area, which is proportionately much more likely.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 5 |
Locobase ID | 13461 |
Railroad | Onda al Grao de Castellon |
Country | Spain |
Whyte | 0-6-2T |
Number in Class | 1 |
Road Numbers | 5, 7 |
Gauge | 75 cm |
Number Built | 1 |
Builder | Krauss |
Year | 1890 |
Valve Gear | Heusinger |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | 11.81 / 3.60 |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | 11.81 / 3.60 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | 41,667 / 18,900 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 41,667 / 18,900 |
Tender Water Capacity (gals / ML) | 554 / 2.10 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 30 / 762 |
Boiler Pressure (psi / kPa) | 142.10 / 980 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11.69" x 13.7" / 297x348 (1) |
Low Pressure Cylinders (dia x stroke) (in / mm) | 18.58" x 13.7" / 472x348 (1) |
Tractive Effort (lbs / kg) | 5400 / 2449.40 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | |
Grate Area (sq ft / m2) | 9.69 / 0.90 |
Evaporative Heating Surface (sq ft / m2) | 418 / 38.84 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 418 / 38.84 |
Evaporative Heating Surface/Cylinder Volume | 491.23 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1377 |
Same as above plus superheater percentage | 1377 |
Same as above but substitute firebox area for grate area | |
Power L1 | |
Power MT |