Data from [], the web site of the Spanish National Railway. Works numbers were 3764-3765 in 1897.
The West Galicia was soon absorbed by the Oeste. The 0211 was retired in 1957, the Calda de Reyes went seven years later in 1964.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | ESPA-A/031-0211 |
| Locobase ID | 3424 |
| Railroad | West Galicia |
| Country | Spain |
| Whyte | 0-6-2T |
| Number in Class | 2 |
| Road Numbers | 441-442 |
| Gauge | 5'6" |
| Number Built | 2 |
| Builder | Kitson & Co |
| Year | 1897 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 11.50 / 3.50 |
| Engine Wheelbase (ft / m) | 17.75 / 5.41 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.65 |
| Overall Wheelbase (engine & tender) (ft / m) | 17.75 / 5.41 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | 29,006 / 13,157 |
| Weight on Drivers (lbs / kg) | 86,236 / 39,116 |
| Engine Weight (lbs / kg) | 111,770 / 50,698 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 1199 / 4.54 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.70 / 2 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 48 / 24 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 55 / 1397 |
| Boiler Pressure (psi / kPa) | 149.40 / 1030 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 17.01" x 24.02" / 432x610 |
| Tractive Effort (lbs / kg) | 16,047 / 7278.81 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.37 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 202 - 1.772" / 45 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 10.01 / 3.05 |
| Firebox Area (sq ft / m2) | 100.11 / 9.30 |
| Grate Area (sq ft / m2) | 20.99 / 1.95 |
| Evaporative Heating Surface (sq ft / m2) | 1027 / 95.45 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1027 / 95.45 |
| Evaporative Heating Surface/Cylinder Volume | 162.56 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 3136 |
| Same as above plus superheater percentage | 3136 |
| Same as above but substitute firebox area for grate area | 14,956 |
| Power L1 | 3311 |
| Power MT | 253.94 |