Data from [], the web site of the Spanish National Railway (21 April 2003). Works numbers were 258-261.
The number of tubes and flues, firebox heating surface, and tube length is identical to the Andaluces 4105-4119 class (Locobase 3370), but the heating surface given for the two differs by almost 16 sq meters. Diagrams show identical wheelbases (which indicates that the tube length remained the same), but the diagram for 2049 shows the higher tube surface area.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 140-2049 |
Locobase ID | 5506 |
Railroad | Oeste |
Country | Spain |
Whyte | 2-8-0 |
Number in Class | 4 |
Road Numbers | 941-944/140-2049 a 2052 |
Gauge | 5'6" |
Number Built | 4 |
Builder | Babcock & Wilcox |
Year | 1928 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 15.32 / 4.67 |
Engine Wheelbase (ft / m) | 24.08 / 7.34 |
Ratio of driving wheelbase to overall engine wheelbase | 0.64 |
Overall Wheelbase (engine & tender) (ft / m) | 49.08 / 14.96 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 28,660 / 13,000 |
Weight on Drivers (lbs / kg) | 116,514 / 52,850 |
Engine Weight (lbs / kg) | 134,482 / 61,000 |
Tender Loaded Weight (lbs / kg) | 57,651 / 26,150 |
Total Engine and Tender Weight (lbs / kg) | 192,133 / 87,150 |
Tender Water Capacity (gals / ML) | 2600 / 9.85 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4.40 / 4 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 49 / 24.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 55.50 / 1410 |
Boiler Pressure (psi / kPa) | 171.10 / 1180 |
High Pressure Cylinders (dia x stroke) (in / mm) | 19.69" x 25.98" / 500x660 |
Tractive Effort (lbs / kg) | 26,394 / 11972.13 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.41 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 108 - 1.969" / 50 |
Flues (number - dia) (in / mm) | 21 - 5.236" / 133 |
Flue/Tube length (ft / m) | 12.17 / 3.71 |
Firebox Area (sq ft / m2) | 120.56 / 11.20 |
Grate Area (sq ft / m2) | 24.97 / 2.32 |
Evaporative Heating Surface (sq ft / m2) | 1423 / 132.20 |
Superheating Surface (sq ft / m2) | 280 / 26 |
Combined Heating Surface (sq ft / m2) | 1703 / 158.20 |
Evaporative Heating Surface/Cylinder Volume | 155.42 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4272 |
Same as above plus superheater percentage | 4956 |
Same as above but substitute firebox area for grate area | 23,928 |
Power L1 | 7858 |
Power MT | 594.74 |