Data from [], the web site of the Spanish National Railway. See also the history of the Santander-Mediterraneo in the Euroferroviarios blog: [
]. The locomotives were produced in batches in 1927-1929; their works numbers were 175-180, 207-210, 300-311.
The author of the Euroferroviarios entry notes that these Consolidations were of British design, but produced locally at B & W in Galindo Viscayo. 22 were completed for mainlines service of both passenger and freight trains, while four were used for switching. S-M procured an additional boiler to provide parts as well as auxiliary service. It did not have a work number.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 101/140-2505 |
Locobase ID | 3372 |
Railroad | Santander-Mediterraneo |
Country | Spain |
Whyte | 2-8-0 |
Number in Class | 26 |
Road Numbers | 101-122/140-2505 a 140-2526 |
Gauge | 5'6" |
Number Built | 26 |
Builder | Babcock & Wilcox |
Year | 1927 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 17.06 / 5.20 |
Engine Wheelbase (ft / m) | 26.25 / 8 |
Ratio of driving wheelbase to overall engine wheelbase | 0.65 |
Overall Wheelbase (engine & tender) (ft / m) | 55.81 / 17.01 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 38,030 / 17,250 |
Weight on Drivers (lbs / kg) | 152,119 / 69,000 |
Engine Weight (lbs / kg) | 180,999 / 82,100 |
Tender Loaded Weight (lbs / kg) | 106,373 / 48,250 |
Total Engine and Tender Weight (lbs / kg) | 287,372 / 130,350 |
Tender Water Capacity (gals / ML) | 5201 / 19.70 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 6.60 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 63 / 31.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 61.40 / 1560 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 23.62" x 25.98" / 600x660 |
Tractive Effort (lbs / kg) | 40,753 / 18485.27 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.73 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 189 - 1.772" / 45 |
Flues (number - dia) (in / mm) | 24 - 4.882" / 124 |
Flue/Tube length (ft / m) | 16.40 / 5 |
Firebox Area (sq ft / m2) | 169.47 / 15.75 |
Grate Area (sq ft / m2) | 37.66 / 3.50 |
Evaporative Heating Surface (sq ft / m2) | 2109 / 196 |
Superheating Surface (sq ft / m2) | 560 / 52.04 |
Combined Heating Surface (sq ft / m2) | 2669 / 248.04 |
Evaporative Heating Surface/Cylinder Volume | 160.07 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 7649 |
Same as above plus superheater percentage | 9255 |
Same as above but substitute firebox area for grate area | 41,647 |
Power L1 | 12,614 |
Power MT | 731.25 |