Data from [], the web site of the Spanish National Railway (link no longer active). [] (28 April 2003) reproduces the diagram with all weights and dimensions.Works numbers were 3402-3403 in 1913 and 5365 in 1922.
These later Mallets were still saturated. The first two arrived in 1913, the third joined them in 1922.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 100/060-4021 |
Locobase ID | 5509 |
Railroad | Zafra y Huelva |
Country | Spain |
Whyte | 0-6-6-0 |
Number in Class | 3 |
Road Numbers | 100-102 |
Gauge | 5'6" |
Number Built | 3 |
Builder | Maffei |
Year | 1913 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8.73 / 2.66 |
Engine Wheelbase (ft / m) | 26.12 / 7.96 |
Ratio of driving wheelbase to overall engine wheelbase | 0.33 |
Overall Wheelbase (engine & tender) (ft / m) | 44.46 / 13.55 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 30,865 / 14,000 |
Weight on Drivers (lbs / kg) | 166,449 / 75,500 |
Engine Weight (lbs / kg) | 166,449 / 75,500 |
Tender Loaded Weight (lbs / kg) | 83,776 / 38,000 |
Total Engine and Tender Weight (lbs / kg) | 250,225 / 113,500 |
Tender Water Capacity (gals / ML) | 3899 / 14.77 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 46 / 23 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 48.40 / 1230 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17.72" x 25.2" / 450x640 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 27.56" x 25.2" / 700x640 |
Tractive Effort (lbs / kg) | 39,937 / 18115.14 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.17 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 242 - 2.008" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 14.76 / 4.50 |
Firebox Area (sq ft / m2) | 109.04 / 10.13 |
Grate Area (sq ft / m2) | 30.35 / 2.82 |
Evaporative Heating Surface (sq ft / m2) | 1961 / 182.16 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1961 / 182.16 |
Evaporative Heating Surface/Cylinder Volume | 272.63 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 6164 |
Same as above plus superheater percentage | 6164 |
Same as above but substitute firebox area for grate area | 22,146 |
Power L1 | 2360 |
Power MT | 187.55 |