Stockholm-Vasteras-Bergslagens 2-6-2 Locomotives in Sweden


Class Details by Steve Llanso of Sweat House Media

Class 17 (Locobase 10632)

Data from "Six-Coupled Bogie Tank Locomotive, Great Southern and Western Ry," The Locomotive Magazine, Volume XIII [13] (15 November 1907), p. 204; and Data from "Tank-lok Litt. S7" one of a series of SJ locomotive diagrams archived by Anders Lundbing on [link], last accessed 10 June 2017 (Snabcon AB advertised its tools for mounting RJ45 connectors on bundled cables.) ; and builders' information "SJ Littera S7" in Svenska.lok.se at [link], last accessed 20 April 2024.

Thomas George Betts, new locomotive superintendent of this railway, ordered a quartet of fast-accelerating tanks for the SVB's suburban service. It was a modern design with outside constant-lead radial valve gear actuating piston valves; however, the boiler was still not superheated.

Principal Dimensions by Steve Llanso of Middle Run Media
Class17
Locobase ID10632
RailroadStockholm-Vasteras-Bergslagens (SWB)
CountrySweden
Whyte2-6-2T
Number in Class4
Road Numbers17
GaugeStd
Number Built4
BuilderFalun
Year1907
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)12.14 / 3.70
Engine Wheelbase (ft / m)26.57 / 8.10
Ratio of driving wheelbase to overall engine wheelbase 0.46
Overall Wheelbase (engine & tender) (ft / m)26.57 / 8.10
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)82,321 / 37,340
Engine Weight (lbs / kg)118,829 / 53,900
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)1848 / 7
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 2.20 / 2
Minimum weight of rail (calculated) (lb/yd / kg/m)46 / 23
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)61 / 1550
Boiler Pressure (psi / kPa)156.60 / 1080
High Pressure Cylinders (dia x stroke) (in / mm)17.72" x 22.83" / 450x580
Tractive Effort (lbs / kg)15,643 / 7095.55
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.26
Heating Ability
Tubes (number - dia) (in / mm)
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)95.80 / 8.90
Grate Area (sq ft / m2)18.84 / 1.75
Evaporative Heating Surface (sq ft / m2)1076 / 100
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1076 / 100
Evaporative Heating Surface/Cylinder Volume165.12
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2950
Same as above plus superheater percentage2950
Same as above but substitute firebox area for grate area15,002
Power L13799
Power MT305.22

All material Copyright © SteamLocomotive.com
Wes Barris