Data from Litt-E9, one of a series of SJ locomotive diagrams archived by Anders Lundbing on [], last accessed 10 June 2017. See also the Bergslagen Railway Society's page at , last accessed 2 June 2015. Works numbers were 1880-1882 in 1931, 2025-2027 in 1936.
These mixed-traffic locomotives were the first Swedish eight-coupleds to lead with a bogie. The 1936 trio trailed tenders carrying 6 tonnes (6.6 short tons) of coal and 17.5 cu m (4,308 US gallons) of water; they weighed 41,800 kg loaded. Taken onto the Statens Jarnvagar (SJ) roster in 1945, they continued operating on the HNJ until retired in 1957.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | G12/E9 |
Locobase ID | 20217 |
Railroad | Halmstad-NSssjö (HNJ)/Statens Jarnvagar |
Country | Sweden |
Whyte | 4-8-0 |
Number in Class | 6 |
Road Numbers | 42-47/1757-1762 |
Gauge | Std |
Number Built | 6 |
Builder | Nydqvist & Holm (NOHAB) |
Year | 1931 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 16.24 / 4.95 |
Engine Wheelbase (ft / m) | 28.22 / 8.60 |
Ratio of driving wheelbase to overall engine wheelbase | 0.58 |
Overall Wheelbase (engine & tender) (ft / m) | 47.57 / 14.50 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 28,219 / 12,800 |
Weight on Drivers (lbs / kg) | 112,877 / 51,200 |
Engine Weight (lbs / kg) | 162,040 / 73,500 |
Tender Loaded Weight (lbs / kg) | 83,776 / 38,000 |
Total Engine and Tender Weight (lbs / kg) | 245,816 / 111,500 |
Tender Water Capacity (gals / ML) | 3960 / 15 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5.50 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 47 / 23.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 55.10 / 1400 |
Boiler Pressure (psi / kPa) | 198.70 / 1370 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17.72" x 24.02" / 450x610 (3) |
Tractive Effort (lbs / kg) | 34,678 / 15729.69 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.26 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 125 - 1.89" / 48 |
Flues (number - dia) (in / mm) | 28 - 5.236" / 133 |
Flue/Tube length (ft / m) | 14.76 / 4.50 |
Firebox Area (sq ft / m2) | 152.85 / 14.20 |
Grate Area (sq ft / m2) | 30.14 / 2.80 |
Evaporative Heating Surface (sq ft / m2) | 1632 / 151.60 |
Superheating Surface (sq ft / m2) | 576 / 53.50 |
Combined Heating Surface (sq ft / m2) | 2208 / 205.10 |
Evaporative Heating Surface/Cylinder Volume | 158.69 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5989 |
Same as above plus superheater percentage | 7546 |
Same as above but substitute firebox area for grate area | 38,268 |
Power L1 | 13,450 |
Power MT | 1050.78 |