Based on Google translation of [] (visited 16 August 2002). The webpage had an article from Schweizerische Bauzeitung (Swiss Polytechnic Review) dated October 14, 1916 (Vol 68, #16).
The article describes the backround of this particular rack design, which is a modified Abt system. The innovation in the provision of two sets of cylinders. On those stretches where adhesion working was sufficient, the outside cylinders drove Hall-type cranks through Heusinger valve gear. When they entered the rack sections, the locomotives switched to compound working, adding inside cylinders which drove the rack pinion through Joy gear.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 5305 |
Railroad | Brigue-Furka-Disentis Rack Railroad |
Country | Switzerland |
Whyte | 2-6-0RT |
Number in Class | 10 |
Road Numbers | |
Gauge | Std |
Number Built | 10 |
Builder | SLM |
Year | 1916 |
Valve Gear | various |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 11.15 / 3.40 |
Engine Wheelbase (ft / m) | 17.49 / 5.33 |
Ratio of driving wheelbase to overall engine wheelbase | 0.64 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | 92,638 / 42,020 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 686 / 2.60 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 35.80 / 909 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16.54" x 18.9" / 420x480 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 22.05" x 17.72" / 560x450 |
Tractive Effort (lbs / kg) | 31,164 / 14135.77 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | 103 - 1.77" / 45 |
Flues (number - dia) (in / mm) | 15 - 5" / 127 |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 73.49 / 6.83 |
Grate Area (sq ft / m2) | 15.06 / 1.40 |
Evaporative Heating Surface (sq ft / m2) | 717 / 66.64 |
Superheating Surface (sq ft / m2) | 185 / 17.19 |
Combined Heating Surface (sq ft / m2) | 902 / 83.83 |
Evaporative Heating Surface/Cylinder Volume | 152.55 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3059 |
Same as above plus superheater percentage | 3701 |
Same as above but substitute firebox area for grate area | 18,060 |
Power L1 | 4254 |
Power MT |