Bone-Guelma 0-6-0 Locomotives in Tunisia


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 7425)

Data from Titre Exposition universelle internationale de 1889 a Paris. Rapports du jury internationale. Auteur - Volume France. Ministere du Commerce, de l'industrie. Picard, Alfred, ed. Volume Groupe VI - -Outillage et precedes des industries mecaniques. Electricite (5e partie) Classes 60 a 63. Rapport sur le materiel des chemins de fer. p. 302 ([link] (accessed 1 September 2005).

Built for service in North Africa, this little tank had to negotiate a tightly curved alignment. To do so, the builder gave the rear axle 80 mm of play (ca 3"). One noticeable lack -- braking other than shoes pressed against the rear two driver sets.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID7425
RailroadBone-Guelma
CountryTunisia
Whyte0-6-0T
Number in Class
Road Numbers
GaugeMetre
Number Built
BuilderBatignolles
Year1889
Valve GearAllan
Locomotive Length and Weight
Driver Wheelbase (ft / m) 8.86 / 2.70
Engine Wheelbase (ft / m) 8.86 / 2.70
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m) 8.86 / 2.70
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)65,191 / 29,570
Engine Weight (lbs / kg)65,191 / 29,570
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)950 / 3.60
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 1.10 / 1
Minimum weight of rail (calculated) (lb/yd / kg/m)36 / 18
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)43.30 / 1100
Boiler Pressure (psi / kPa)130.50 / 900
High Pressure Cylinders (dia x stroke) (in / mm)14.57" x 20.47" / 370x520
Tractive Effort (lbs / kg)11,132 / 5049.40
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.86
Heating Ability
Tubes (number - dia) (in / mm)106 - 1.969" / 50
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)12.47 / 3.80
Firebox Area (sq ft / m2)62.41 / 5.80
Grate Area (sq ft / m2) 9.90 / 0.92
Evaporative Heating Surface (sq ft / m2)743 / 69.04
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)743 / 69.04
Evaporative Heating Surface/Cylinder Volume188.09
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1292
Same as above plus superheater percentage1292
Same as above but substitute firebox area for grate area8145
Power L12515
Power MT255.16

All material Copyright © SteamLocomotive.com
Wes Barris