Data from card number 619 "Locomotives de L'Algerie", HMP, 8 Rue de Tournon, Paris, archived at [], supplemented by "Recent Locomotives for the Bone-Guelma Railway", Locomotive Magazine, Volume XX [20] (15 October1914), p. 226-227
Photo shows a large, tall Decapod with Belpaire firebox, straight boiler pitched high, piston valves, small dome flanked by small sandboxes
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 221 |
Locobase ID | 14726 |
Railroad | Bone-Guelma (et Prolongemonts) |
Country | Tunisia |
Whyte | 2-10-0 |
Number in Class | 15 |
Road Numbers | 221-2354 |
Gauge | Std |
Number Built | 15 |
Builder | SACM |
Year | 1910 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 144,623 / 65,600 |
Engine Weight (lbs / kg) | 161,599 / 73,300 |
Tender Loaded Weight (lbs / kg) | 75,178 / 34,100 |
Total Engine and Tender Weight (lbs / kg) | 236,777 / 107,400 |
Tender Water Capacity (gals / ML) | 3168 / 12 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 6.60 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 48 / 24 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 55.10 / 1400 |
Boiler Pressure (psi / kPa) | 169.70 / 1170 |
High Pressure Cylinders (dia x stroke) (in / mm) | 24.41" x 25.59" / 620x650 |
Tractive Effort (lbs / kg) | 39,917 / 18106.07 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.62 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 152 - 1.772" / 45 |
Flues (number - dia) (in / mm) | 24 - 5" / 127 |
Flue/Tube length (ft / m) | 13.78 / 4.20 |
Firebox Area (sq ft / m2) | 170.07 / 15.80 |
Grate Area (sq ft / m2) | 29.71 / 2.76 |
Evaporative Heating Surface (sq ft / m2) | 1553 / 144.32 |
Superheating Surface (sq ft / m2) | 442 / 41.08 |
Combined Heating Surface (sq ft / m2) | 1995 / 185.40 |
Evaporative Heating Surface/Cylinder Volume | 112.04 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5042 |
Same as above plus superheater percentage | 6151 |
Same as above but substitute firebox area for grate area | 35,210 |
Power L1 | 7175 |
Power MT | 546.88 |