Data from Roy V Wright (Ed.) 1912 Locomotive Cyclopedia of American Practice, Sixth Edition (New York: Simmons-Boardman Publishing Company, 1912), p. 153. Works numbers were 4547-4548 in April 1910.
Located in Calhoun County, Ill, the CC&B exploited a coal outcropping through a drift mine. Originally incorporated before 1882 as the Thomas Coal Company, the corporate name of CC&B only applied between 1907 and 1911.
To take men in and haul coal out, they needed a low-profile mine locomotive. Locobase hasn't determined the track gauge.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 32 |
| Locobase ID | 15028 |
| Railroad | Bethlehem Steel |
| Country | USA |
| Whyte | 0-4-0ST |
| Number in Class | 2 |
| Road Numbers | 32-33 |
| Gauge | Std |
| Number Built | 2 |
| Builder | Porter |
| Year | 1910 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 5 / 1.52 |
| Engine Wheelbase (ft / m) | 5 / 1.52 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 5 / 1.52 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 81,500 / 36,968 |
| Engine Weight (lbs / kg) | 81,500 / 36,968 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 68 / 34 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 40 / 1016 |
| Boiler Pressure (psi / kPa) | 170 / 1170 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 15" x 20" / 381x508 |
| Tractive Effort (lbs / kg) | 16,256 / 7373.61 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.01 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 76.80 / 7.13 |
| Grate Area (sq ft / m2) | 14.08 / 1.31 |
| Evaporative Heating Surface (sq ft / m2) | 808 / 75.07 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 808 / 75.07 |
| Evaporative Heating Surface/Cylinder Volume | 197.56 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2394 |
| Same as above plus superheater percentage | 2394 |
| Same as above but substitute firebox area for grate area | 13,056 |
| Power L1 | 3303 |
| Power MT | 178.70 |