Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 64, p. 99. See also the history of Kaulton, Ala at Locobase 13122. Works number was 55413 in March 1922.
For some reason, the KLC specified that this typical logging Mogul have a boiler pressed to 200 psi. Combined with a relatively low adhesion weight, the 17 had a significantly lower factor of adhesion than most of its timber-harvesting counterparts.
Nevertheless, the 17 apparently remained in service for decades. It ended its days on the Gulf State Paper's rails. A note in the specs volume shows that it was scrapped on 6/6/1950.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 17 |
Locobase ID | 15221 |
Railroad | Kaul Lumber Company |
Country | USA |
Whyte | 2-6-0 |
Number in Class | 1 |
Road Numbers | 17 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1922 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 12 / 3.66 |
Engine Wheelbase (ft / m) | 19.75 / 6.02 |
Ratio of driving wheelbase to overall engine wheelbase | 0.61 |
Overall Wheelbase (engine & tender) (ft / m) | 47.92 / 14.61 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 99,000 / 44,906 |
Engine Weight (lbs / kg) | 113,000 / 51,256 |
Tender Loaded Weight (lbs / kg) | 87,000 / 39,463 |
Total Engine and Tender Weight (lbs / kg) | 200,000 / 90,719 |
Tender Water Capacity (gals / ML) | 4000 / 15.15 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 8 / 7 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 55 / 27.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 48 / 1219 |
Boiler Pressure (psi / kPa) | 200 / 1380 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 24" / 457x610 |
Tractive Effort (lbs / kg) | 27,540 / 12491.95 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.59 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 206 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11 / 3.35 |
Firebox Area (sq ft / m2) | 109 / 10.13 |
Grate Area (sq ft / m2) | 20.70 / 1.92 |
Evaporative Heating Surface (sq ft / m2) | 1286 / 119.47 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1286 / 119.47 |
Evaporative Heating Surface/Cylinder Volume | 181.90 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4140 |
Same as above plus superheater percentage | 4140 |
Same as above but substitute firebox area for grate area | 21,800 |
Power L1 | 4144 |
Power MT | 276.85 |