Data from the Twelfth Annual Report of the American Railway Master Mechanics' Association, May 13th-May 15th, 1879, page 83. See also DeGolyer, Volume 7, p. 31. Works numbers ran 3496, 3500-3503, 3505-3506, 3508 in November 1873; 3512, 3515-3518 in December.
In discussing the relative merits of deep versus shallow fireboxes, Mr Sedgley of the LS&MS described tests between the straight-boilered Moguls from Baldwin and seven wagon-top Eight-wheelers (Locobase 9518). Sedgley said that the seven 2-6-0s averaged 41.95 loaded cars per train mile over a total mileage of 228,057 and consumed just a bit less coal per car than did the Eight-wheelers.
NB: Boiler pressure is an estimate and the heating surface of the tubes (no firebox area is given) is measured from the inside; water side area would be 8-10% greater.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | L |
Locobase ID | 9517 |
Railroad | Lake Shore & Michigan Southern |
Country | USA |
Whyte | 2-6-0 |
Number in Class | 13 |
Road Numbers | 479-491 |
Gauge | 4' 9.2" |
Number Built | 13 |
Builder | Burnham, Parry, Williams & Co |
Year | 1873 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 14.50 |
Engine Wheelbase (ft / m) | 22 |
Ratio of driving wheelbase to overall engine wheelbase | 0.66 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 2500 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 57 / 1372 |
Boiler Pressure (psi / kPa) | 120 / 900 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 24" / 406x610 |
Tractive Effort (lbs / kg) | 10,995 / 4987.25 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | 148 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.19 / 3.40 |
Firebox Area (sq ft / m2) | |
Grate Area (sq ft / m2) | 15.80 / 1.47 |
Evaporative Heating Surface (sq ft / m2) | 846 / 78.62 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 846 / 78.62 |
Evaporative Heating Surface/Cylinder Volume | 151.34 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1896 |
Same as above plus superheater percentage | 1896 |
Same as above but substitute firebox area for grate area | |
Power L1 | |
Power MT |