Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 65, p. 45. Works number was 54090 in November 1920.
Identical to the Calcasieu superheated logging Consolidation described in Locobase 14933 and owned by the same company, the 93 first operated in Longville, La. It later joined the Calcasieu #68 on the Longview, Portland & Northern. Unlike the 68, which was later sold to Mexico, the 93 was scrapped after 35 years' service by the LP&N.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 93 |
Locobase ID | 14935 |
Railroad | Longville Lumber |
Country | USA |
Whyte | 2-6-2 |
Number in Class | 1 |
Road Numbers | 93 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1920 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.25 / 3.12 |
Engine Wheelbase (ft / m) | 26.83 / 8.18 |
Ratio of driving wheelbase to overall engine wheelbase | 0.38 |
Overall Wheelbase (engine & tender) (ft / m) | 50.50 / 15.39 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 101,000 / 45,813 |
Engine Weight (lbs / kg) | 130,000 / 58,967 |
Tender Loaded Weight (lbs / kg) | 90,000 / 40,823 |
Total Engine and Tender Weight (lbs / kg) | 220,000 / 99,790 |
Tender Water Capacity (gals / ML) | 4500 / 17.05 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 6 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 56 / 28 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 47 / 1194 |
Boiler Pressure (psi / kPa) | 200 / 1380 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 24" / 432x610 |
Tractive Effort (lbs / kg) | 25,088 / 11379.74 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.03 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 114 - 2" / 51 |
Flues (number - dia) (in / mm) | 21 - 5.375" / 137 |
Flue/Tube length (ft / m) | 15 / 4.57 |
Firebox Area (sq ft / m2) | 104 / 9.66 |
Grate Area (sq ft / m2) | 18.70 / 1.74 |
Evaporative Heating Surface (sq ft / m2) | 1438 / 133.59 |
Superheating Surface (sq ft / m2) | 344 / 31.96 |
Combined Heating Surface (sq ft / m2) | 1782 / 165.55 |
Evaporative Heating Surface/Cylinder Volume | 227.89 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3740 |
Same as above plus superheater percentage | 4451 |
Same as above but substitute firebox area for grate area | 24,752 |
Power L1 | 12,548 |
Power MT | 821.69 |