Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist Universitym Volume 45, p. 136. Works number was 40948 in November 1913.
The Southern did not operate the 30 for long before selling it to the F B Williams Cypress Company in January 1916. The engine was to placed in "good condition" using parts supplied by Baldwin's Extra Work Department.
Williams Cypress later sold the 30 to the Orange Grove Plantation and Orange Grove sold it to Sterling Sugar, which operated the little Mogul for years (possibly until 1948).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 30 |
Locobase ID | 14061 |
Railroad | Southern Railway & Navigation |
Country | USA |
Whyte | 2-6-2 |
Number in Class | 1 |
Road Numbers | 30 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1913 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8 / 2.44 |
Engine Wheelbase (ft / m) | 21.33 / 6.50 |
Ratio of driving wheelbase to overall engine wheelbase | 0.38 |
Overall Wheelbase (engine & tender) (ft / m) | 43 / 13.11 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 45,000 / 20,412 |
Engine Weight (lbs / kg) | 62,000 / 28,123 |
Tender Loaded Weight (lbs / kg) | 50,000 / 22,680 |
Total Engine and Tender Weight (lbs / kg) | 112,000 / 50,803 |
Tender Water Capacity (gals / ML) | 2500 / 9.47 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 25 / 12.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 37 / 940 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 12" x 18" / 305x457 |
Tractive Effort (lbs / kg) | 10,718 / 4861.61 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.20 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 90 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10.50 / 3.20 |
Firebox Area (sq ft / m2) | 60 / 5.57 |
Grate Area (sq ft / m2) | 13.30 / 1.24 |
Evaporative Heating Surface (sq ft / m2) | 551 / 51.19 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 551 / 51.19 |
Evaporative Heating Surface/Cylinder Volume | 233.47 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2394 |
Same as above plus superheater percentage | 2394 |
Same as above but substitute firebox area for grate area | 10,800 |
Power L1 | 4003 |
Power MT | 588.34 |