Data from [], supplemented by DeGolyer, Volume 80, pp. 298+. Works number was 59173 in May 1926.
Split saddle-tanker served Simpson Logging on their Peninsular Railway in Shelton, Wash, where the specifications indicated a maximum grade of 5% (or "possibly 6%") on 60 lb/yard (30 kg/metre) rail around 30 degree (193 foot/59 metre radii).
Like the other Baldwin 2-6-6-2 tanks, all four of 13's cylinders were served by piston valves--8" (203 mm) diameter for HP, 12" (305 mm) for the LP cylinders.
The 13 put in 30 years beforel her retirement in 1956, after which she was scrapped.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Sophus Jacobson |
Locobase ID | 4062 |
Railroad | Simpson Logging |
Country | USA |
Whyte | 2-6-6-2T |
Number in Class | 1 |
Road Numbers | 13 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1926 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 16 / 4.88 |
Engine Wheelbase (ft / m) | 37.75 / 11.51 |
Ratio of driving wheelbase to overall engine wheelbase | 0.42 |
Overall Wheelbase (engine & tender) (ft / m) | 37.75 / 11.51 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 200,000 / 90,719 |
Engine Weight (lbs / kg) | 238,000 / 107,955 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 2500 / 9.47 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1000 / 3785 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 56 / 28 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 44 / 1118 |
Boiler Pressure (psi / kPa) | 200 / 1380 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 24" / 457x610 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 28" x 24" / 711x610 |
Tractive Effort (lbs / kg) | 42,517 / 19285.41 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.70 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 124 - 2" / 51 |
Flues (number - dia) (in / mm) | 18 - 5.375" / 137 |
Flue/Tube length (ft / m) | 17 / 5.18 |
Firebox Area (sq ft / m2) | 128 / 11.89 |
Grate Area (sq ft / m2) | 26.20 / 2.43 |
Evaporative Heating Surface (sq ft / m2) | 1654 / 153.72 |
Superheating Surface (sq ft / m2) | 358 / 33.27 |
Combined Heating Surface (sq ft / m2) | 2012 / 186.99 |
Evaporative Heating Surface/Cylinder Volume | 234.09 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5240 |
Same as above plus superheater percentage | 6183 |
Same as above but substitute firebox area for grate area | 30,208 |
Power L1 | 4730 |
Power MT | 312.84 |