Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 35, p. 283. Works number was 34563 in April 1910.
This Washington State logging road of Bryant, Wash was closed and dismantled by 1927 and the Carlisle & Northern of Onalaska, Wash bought the 1 and renumbered 901. Later the Newaukum Valley of Napavine, Wash bought the 901, operated it, and sold it in 1942 to Valley & Siletz, which renumbered it 57 in Hoskins, Ore and ran it until it was scrapped in December 1955.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1 |
Locobase ID | 13681 |
Railroad | Marysville & Northern |
Country | USA |
Whyte | 2-8-2 |
Number in Class | 1 |
Road Numbers | 1 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1910 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13.08 / 3.99 |
Engine Wheelbase (ft / m) | 27 / 8.23 |
Ratio of driving wheelbase to overall engine wheelbase | 0.48 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 132,900 / 60,282 |
Engine Weight (lbs / kg) | 171,700 / 77,882 |
Tender Loaded Weight (lbs / kg) | 80,000 / 36,287 |
Total Engine and Tender Weight (lbs / kg) | 251,700 / 114,169 |
Tender Water Capacity (gals / ML) | 4000 / 15.15 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2800 / 10,598 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 55 / 27.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 48 / 1219 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 20" x 28" / 508x711 |
Tractive Effort (lbs / kg) | 31,733 / 14393.86 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.19 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 350 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 16.50 / 5.03 |
Firebox Area (sq ft / m2) | 148 / 13.75 |
Grate Area (sq ft / m2) | 41.30 / 3.84 |
Evaporative Heating Surface (sq ft / m2) | 3156 / 293.31 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 3156 / 293.31 |
Evaporative Heating Surface/Cylinder Volume | 310.02 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 6608 |
Same as above plus superheater percentage | 6608 |
Same as above but substitute firebox area for grate area | 23,680 |
Power L1 | 4899 |
Power MT | 325.07 |