Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 21, p. 196. See also at [], last accessed 29 October 2022. Works number was 16273 in October 1898 and 18675-18676 in February 1901.
Chartered before the Civil War, the A&NC ran from Goldsboro, NC to New Bern and on to the Inner Banks, where Morehead City provided the terminus on the west side. By the time the railroad ordered the 14 in 1898, the total distance was 95 miles (153 lm). In 1904, the Norfolk & Southern leased the A&NC, continuing to operate it until l935, when the A&NC withdrew the lease.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 14 / B-4 |
Locobase ID | 12281 |
Railroad | Atlantic & North Carolina |
Country | USA |
Whyte | 4-4-0 |
Number in Class | 3 |
Road Numbers | 14, 18-19 / 43 / 37 / 49 |
Gauge | Std |
Number Built | 3 |
Builder | Burnham, Williams & Co |
Year | 1898 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8.33 / 2.54 |
Engine Wheelbase (ft / m) | 23.27 / 7.09 |
Ratio of driving wheelbase to overall engine wheelbase | 0.36 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 54,000 / 24,494 |
Engine Weight (lbs / kg) | 84,000 / 38,102 |
Tender Loaded Weight (lbs / kg) | 51,000 / 23,133 |
Total Engine and Tender Weight (lbs / kg) | 135,000 / 61,235 |
Tender Water Capacity (gals / ML) | 2600 / 9.85 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 45 / 22.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 60 / 1524 |
Boiler Pressure (psi / kPa) | 165 / 1140 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 24" / 432x610 |
Tractive Effort (lbs / kg) | 16,213 / 7354.10 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.33 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 188 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.83 / 3.61 |
Firebox Area (sq ft / m2) | 123.41 / 11.47 |
Grate Area (sq ft / m2) | 16.50 / 1.53 |
Evaporative Heating Surface (sq ft / m2) | 1280 / 118.96 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1280 / 118.96 |
Evaporative Heating Surface/Cylinder Volume | 202.85 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2723 |
Same as above plus superheater percentage | 2723 |
Same as above but substitute firebox area for grate area | 20,363 |
Power L1 | 4961 |
Power MT | 405.08 |